Accelerated Life Testing Analysis
Accelerated life testing analysis fits a life distribution whose scale depends on stress through a life-stress relationship such as Arrhenius or inverse power law, then extrapolates life at normal use conditions.
가속 수명 시험 분석은 수명 분포의 척도가 Arrhenius 나 역멱 법칙 같은 수명-스트레스 관계를 따르도록 함께 적합해, 정상 사용 조건에서의 수명을 외삽하는 방법입니다.
Also known as: Accelerated Life Model (Arrhenius Temperature Stress); Accelerated Life Model (Arrhenius–Weibull)
다른 이름: 가속 수명 모형(Arrhenius 온도 스트레스); 가속 수명 모형(Arrhenius–Weibull)
We tested parts at 85, 105 and 125 °C with some survivors; how do I estimate the activation energy and the B10 life at 40 °C use temperature?
부품을 85, 105, 125 °C 에서 시험했고 끝까지 안 고장 난 것도 있는데, 활성화 에너지와 40 °C 사용 조건의 B10 수명을 어떻게 추정하나요?
Combine a Weibull, lognormal or exponential life distribution with a life-stress model for its characteristic life, for example ln L = a + b/T (Arrhenius), and fit all stress levels jointly by maximum likelihood with censored units included. The activation energy is b times Boltzmann's constant, and the fitted relation gives life, B-life and acceleration factors with confidence intervals at the use stress.
When to use Accelerated Life Testing Analysis
- Units were tested at several elevated stress levels (temperature, voltage, humidity) to obtain failures quickly.
- Some units survived the test and must be treated as right-censored.
- You need life, B-life or acceleration factors at a lower use stress.
When to use something else
- All units were tested at a single condition; use life distribution identification.
- The response is a measured degradation level rather than a failure time; use degradation analysis.
Assumptions and requirements
- The same failure mechanism operates at every stress, so the shape parameter is common.
- The chosen life-stress relation holds from the test stresses down to the use stress.
- Censoring is independent of failure risk.
What the analysis reports
- Life-stress parameters with Fisher-matrix intervals, including activation energy (eV) or power exponent
- Common Weibull β or lognormal σ
- Characteristic life per tested stress level and acceleration factors relative to the use stress with intervals
- Characteristic life, B-life and mean life at the use stress with delta-method intervals
How to report it
A Weibull–Arrhenius model fitted to [value] units ([value] failures) at [value] stress levels gave an activation energy of [value] eV (SE = [value]) with a common β = [value]; at the use condition ([value]) the B10 life was [value] (95% CI [[value], [value]]).
Common variants
자주 쓰는 설정
The same analysis with settings already chosen. Each runs Accelerated Life Testing Analysis itself, at the same price.
- Accelerated Life Model (Inverse Power Law) — life stress set to “inverse_power”
Related methods
- Life Distribution Identification
- Accelerated Failure Time Model (Log-normal, Log-logistic)
- Accelerated Stability Prediction (Arrhenius)
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with lifelines.
독립 계산. lifelines 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Accelerated Life Testing Analysis on Quorant
- Data you need
- a table (CSV or Excel) with a time variable, an event indicator and predictor (feature) columns
- Price
- 600 credits for one analysis up to 10,000 rows (complexity level 4); larger or wider data costs more. Optional methodologist review: 2400 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.