Batch Process Monitoring (Multiway PCA)
Batch process monitoring by multiway PCA: data are unfolded by batch and within-batch time before PCA, and new batches are checked with T² and Q limits.
배치 공정 감시(다원 PCA) — 자료를 배치와 배치 안 시간으로 펼친 뒤 PCA를 하는 다원 PCA 배치 공정 감시로, 새 배치를 T²와 Q 한계로 점검합니다.
Runs PCA Process Diagnostics (Hotelling T² and Q Residuals) with: .
기본 방법(PCA Process Diagnostics (Hotelling T² and Q Residuals))에 다음 설정을 고정해 실행합니다: .
Each batch is a trajectory over time; how do I tell whether a new batch behaves like the good ones?
배치마다 시간에 따른 궤적이 있는데, 새 배치가 정상 배치처럼 움직이는지 어떻게 알 수 있나요?
Multiway PCA models the whole trajectory of normal batches and flags batches whose T² or Q statistic exceeds control limits. It runs PCA Process Diagnostics (Hotelling T² and Q Residuals) with batch (batch column); batch_time (time column) supplied as an extra input; checks and report follow PCA Process Diagnostics (Hotelling T² and Q Residuals).
When to use Batch Process Monitoring (Multiway PCA)
- You have a set of good reference batches with measurements over batch time.
- Batches have the same length or can be aligned.
When to use something else
- Data are a continuous process without batches; ordinary PCA monitoring fits.
- You have nothing to give for batch; PCA Process Diagnostics (Hotelling T² and Q Residuals) runs without it.
What you still provide
- Data: a table (CSV or Excel) with predictor (feature) columns.
- batch (batch column)
- batch time (time column)
Assumptions and requirements
The same as for PCA Process Diagnostics (Hotelling T² and Q Residuals):
- Calibration samples represent normal operation and are free of gross outliers.
- Scores and residuals are approximately normal for the limits.
- Variables are scaled appropriately (autoscaling by default).
- In batch mode, batches are aligned on a common time grid (equal length) and at least 5 calibration batches are given; 20 or more are advisable.
What the analysis reports
The output of PCA Process Diagnostics (Hotelling T² and Q Residuals), with the preset shown in the settings:
- T² per sample with the F-based limit A(n²-1)/(n(n-A))F
- Q (SPE) per sample with the Jackson-Mudholkar limit
- Top contributing variable to T² and Q for flagged samples
- Number of components and explained variance
- Optional batch-wise unfolding (multiway PCA, Nomikos-MacGregor) of long-format batch data: batch-level T² and SPE with limits, SPE limits at every time point (g·χ² approximation), evolving T² from the data observed up to each time point, alarm counts and first alarm time per batch
How this is validated
검증 근거
This variant runs the same engine as PCA Process Diagnostics (Hotelling T² and Q Residuals) with the settings above fixed, so the evidence is that method’s: compared with independent computations. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 PCA Process Diagnostics (Hotelling T² and Q Residuals)와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Run this variant
- Data you need
- a table (CSV or Excel) with predictor (feature) columns
- Price
- Same as PCA Process Diagnostics (Hotelling T² and Q Residuals): 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations, as recorded for PCA Process Diagnostics (Hotelling T² and Q Residuals) (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.