Bloch's Law Temporal Summation Fit
Bloch's law states that for brief stimuli the detection threshold depends on the product of intensity and duration: halving the duration doubles the intensity needed. Beyond a critical duration the threshold no longer falls with duration. The method fits this two-part relation in log-log coordinates, with a slope of -1 below the critical duration and a flat (or user-set) slope above it, and locates the critical duration.
블로흐 법칙은 짧은 자극에서는 검출 역치가 강도와 지속시간의 곱에 따라 정해진다는 법칙입니다. 지속시간이 절반이 되면 필요한 강도가 두 배가 되며, 임계 지속시간을 넘으면 역치가 더 이상 줄지 않습니다. 이 방법은 로그-로그 좌표에서 임계 지속시간 아래는 기울기 -1, 위는 평평한 두 구간 직선을 맞추어 임계 지속시간을 찾습니다.
Up to what stimulus duration does the visual (or other sensory) system add up energy completely, and what is the threshold beyond that point?
감각 체계가 에너지를 완전히 합산하는 자극 지속시간의 한계는 어디이고, 그 이후의 역치는 얼마입니까?
The method returns the critical duration with a 95% profile confidence interval, the plateau threshold, the summation constant (intensity times duration below the critical duration), the fit statistics, and an F test of whether the lower slope differs from the -1 that complete summation predicts.
When to use Bloch's Law Temporal Summation Fit
- You measured detection thresholds at several stimulus durations.
- You want the critical duration of temporal summation for a condition or observer.
- You want to test whether summation below the critical duration is complete.
When to use something else
- Your stimulus varies in size rather than duration: use Ricco's Law Spatial Summation Fit
- You want the threshold from raw trial-by-trial responses: use Psychometric Function Fitting
- The threshold changes smoothly with intensity as a power law: use Psychophysical Power Law (Magnitude Estimation)
Assumptions and requirements
- Thresholds measured with the same criterion at every duration
- Log thresholds have roughly constant, normally distributed error
- Durations span both sides of the critical duration
What the analysis reports
- Critical duration and 95% profile CI
- Plateau threshold
- Summation constant
- Lower slope and test of complete summation
- R-squared and residual SD on the log scale
How to report it
A two-segment fit of Bloch's law placed the critical duration at [value] ms (95% profile CI [value] to [value]) with a plateau threshold of [value].
Related methods
- Ricco's Law Spatial Summation Fit
- Psychometric Function Fitting
- Weber Fraction and Weber-Fechner Analysis
How this method is validated
이 방법의 검증 근거
- Independent computation. 2 reference tests compare the results with SciPy and direct computations (formulas, enumeration or simulation) at a stated tolerance of 1e-5.
독립 계산. SciPy·직접 계산(식·열거·모의실험) 대조 참조 시험 2건 통과(허용오차 1e-5).
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Bloch's Law Temporal Summation Fit on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.