Extensional Rheology from Capillary Thinning (CaBER)
Capillary-thinning extensional rheometry (CaBER) infers extensional properties from the decay of a liquid filament's mid-diameter over time, giving a relaxation time, a viscosity and the apparent extensional viscosity.
모세관 박화 신장 유변학(CaBER)은 액체 필라멘트 중앙 지름이 시간에 따라 줄어드는 양상으로 완화시간, 점도, 겉보기 신장 점도 같은 신장 물성을 추정하는 방법입니다.
I recorded the filament diameter over time in a capillary break-up rheometer; how do I get the extensional relaxation time and extensional viscosity?
모세관 파단 유변계로 필라멘트 지름을 시간에 따라 기록했는데, 신장 완화시간과 신장 점도를 어떻게 구하나요?
Fit the thinning window with the elasto-capillary exponential, the visco-capillary linear and a power-law model, pick the regime by AIC, and read the relaxation time from the exponential decay rate or the viscosity from the linear slope. Compute the apparent extensional viscosity from the local thinning rate and surface tension against Hencky strain and, with a known shear viscosity, the Trouton ratio.
When to use Extensional Rheology from Capillary Thinning (CaBER)
- You have filament diameter versus time from a capillary break-up or dripping-onto-substrate experiment.
- You need the extensional relaxation time of a dilute or semi-dilute polymer solution.
- You want apparent extensional viscosity and Trouton ratios against Hencky strain.
When to use something else
- You need shear viscosity or moduli; use steady shear or oscillatory rheometry models.
- The liquid is very low-viscosity and inertia-dominated; use an inertio-capillary analysis rather than these regimes.
Assumptions and requirements
- Surface tension is known and the diameter is the filament mid-diameter in consistent units (m, mm or um).
- The fitting window (fractions of D0) lies in a single thinning regime before break-up.
- Gravity, inertia and evaporation are negligible in the window.
What the analysis reports
- Extensional relaxation time lambda_E and elastic modulus G (elasto-capillary)
- Visco-capillary viscosity and critical time, power-law exponent
- Apparent extensional viscosity, strain rate and Trouton ratio versus Hencky strain
- Break-up time and AIC comparison of regimes
How to report it
The filament thinned elasto-capillarily (R2 = [value]) with an extensional relaxation time of [value] ms, the apparent extensional viscosity reached [value] Pa s at a Hencky strain of [value] (Trouton ratio [value]), and the filament broke at [value] s.
Related methods
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with direct computations (formulas, enumeration or simulation).
독립 계산. 직접 계산(식·열거·모의실험) 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Extensional Rheology from Capillary Thinning (CaBER) on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.