Digital Filtering
Digital filtering removes unwanted frequency components from a sampled signal with a designed low-pass, high-pass, band-pass, band-stop, notch or smoothing filter.
디지털 필터는 저역·고역·대역통과·대역저지·노치·평활 필터를 설계해 표본 신호에서 원치 않는 주파수 성분을 없애는 방법입니다.
Also known as: Zero-Phase Forward–Backward Filtering
다른 이름: 영위상 전후방 필터링
How do I remove high-frequency noise (or mains hum) from my sensor signal without shifting the peaks in time?
센서 신호의 고주파 잡음(또는 전원 험)을 봉우리 위치를 밀지 않고 없애려면 어떻게 하나요?
An IIR filter (Butterworth, Chebyshev I or Bessel) or a windowed FIR filter is designed for the chosen cutoff and order and applied forward and backward so that the output has zero phase shift. Savitzky-Golay and moving-average smoothers and an IIR notch are also available, and the frequency response and before/after spectra show what was removed.
When to use Digital Filtering
- A sampled signal contains noise or drift in a known frequency band.
- You need to remove a single interference frequency such as 50/60 Hz.
- You want smoothing that preserves peak shape (Savitzky-Golay).
When to use something else
- You want to separate trend and cycle in an economic series; use the Hodrick-Prescott or band-pass (Baxter-King) filter.
- You want to estimate a hidden state with uncertainty; use Kalman filtering.
Assumptions and requirements
- Samples are equally spaced and the sampling frequency is known.
- The wanted and unwanted components occupy different frequency bands.
- The record is long relative to the filter length to limit edge effects.
What the analysis reports
- Filtered signal (in the plot data)
- Frequency response (single-pass and effective gain in dB) on 40 frequencies
- Gain at the cutoff frequencies
- Variance retained and total power change before and after filtering
How to report it
The signal (fs = [value] Hz) was low-pass filtered with a fourth-order Butterworth filter (cutoff [value] Hz) applied forward and backward for zero phase; the filtered series retained [value]% of the variance.
Common variants
자주 쓰는 설정
The same analysis with settings already chosen. Each runs Digital Filtering itself, at the same price.
- Polynomial Smoothing Filter (Savitzky–Golay) — type set to “savgol”
- Digital Filtering (Chebyshev Type I) — family set to “chebyshev1”
- Moving-Average Smoothing of a Signal — type set to “moving_average”
- Band-Pass Filtering (Butterworth) — family set to “butterworth”; type set to “bandpass”
- Douglas-Peucker line simplification — type set to “douglas_peucker”
Related methods
How this method is validated
이 방법의 검증 근거
- Automated tests. Checked by automated run tests; no external reference comparison is recorded yet.
자동 시험. 자동 실행 시험을 거칩니다. 외부 참조값과 대조한 기록은 아직 없습니다.
Run Digital Filtering on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Automated run tests; no external reference comparison yet
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.