Dose Proportionality Assessment (Power Model)
Dose proportionality assessment with the power model regresses log exposure on log dose and judges proportionality by whether the 90% confidence interval of the slope lies within limits set by the dose range.
멱함수 모형 용량 비례성 평가는 로그 노출량을 로그 용량에 회귀하고 기울기의 90% 신뢰구간이 용량 범위로 정한 한계 안에 드는지로 비례성을 판정하는 방법입니다.
Does AUC increase in proportion to dose across the doses in my first-in-human study?
최초 임상시험의 용량 범위에서 AUC 가 용량에 비례해 늘어나는지 어떻게 확인하나요?
The power model ln(AUC) = α + β·ln(dose) is fitted, with a random subject intercept when subjects received several doses, and β = 1 means exact proportionality. Following Smith and colleagues, proportionality is concluded when the 90% confidence interval of β lies within 1 + ln(0.80)/ln(r) to 1 + ln(1.25)/ln(r), where r is the ratio of highest to lowest dose.
When to use Dose Proportionality Assessment (Power Model)
- AUC or Cmax is measured at three or more dose levels.
- A crossover or parallel dose-escalation study needs a formal proportionality conclusion.
- The change in dose-normalised exposure over the dose range is to be quantified.
When to use something else
- Only two formulations at one dose are compared; use average bioequivalence analysis.
- Exposure plateaus or saturates within the range; fit a nonlinear Emax-type model instead.
Assumptions and requirements
- Log exposure is linear in log dose over the studied range.
- Residuals on the log scale are normal with constant variance.
- Repeated measures within subjects are handled by a random intercept.
What the analysis reports
- Slope β with 90% confidence interval and the acceptance interval for β
- Conclusion: proportional, not proportional or inconclusive
- Ratio of dose-normalised exposure between highest and lowest dose with interval
- Residual and between-subject variances when a mixed model is used
How to report it
The power model gave β = [value] (90% CI [value], [value]) over a [value]-fold dose range; because the interval lay within the acceptance range [value]–[value], AUC was dose proportional.
Related methods
- Average Bioequivalence Analysis
- Noncompartmental Pharmacokinetic Analysis (NCA)
- Linear Mixed-Effects Model
How this method is validated
이 방법의 검증 근거
- Automated tests. Checked by automated run tests; no external reference comparison is recorded yet.
자동 시험. 자동 실행 시험을 거칩니다. 외부 참조값과 대조한 기록은 아직 없습니다.
Run Dose Proportionality Assessment (Power Model) on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable, predictor (feature) columns and a unit (entity) ID
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Automated run tests; no external reference comparison yet
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.