Skip to content

Methods · Biostatistics · Cytometry

Automated Flow Cytometry Gating (Gaussian Mixture and Density-Valley Gates)

Automated gating separates cell events into populations without hand-drawn gates: marker intensities are transformed (arcsinh or log), a Gaussian mixture with the number of populations chosen by BIC is fitted, each population is gated by an ellipsoid at a chosen probability, and one-dimensional density valleys per marker label each population as positive or negative.

자동 게이팅은 형광 강도를 아크사인 또는 로그로 변환한 뒤 BIC 로 개수를 고른 가우스 혼합모형을 적합하고, 각 집단을 확률 타원 게이트로 나누며, 마커별 밀도 골짜기 기준으로 양성과 음성 표현형을 붙이는 방법입니다.

Which cell populations are in my cytometry sample, how large is each, and what is their marker phenotype?

이 시료에는 어떤 세포 집단이 있고, 각 집단의 비율과 마커 표현형은 어떠할까요?

Each event is assigned to the mixture component with the highest posterior probability if it lies inside that component's ellipsoid gate; events outside every gate are left ungated. The report gives the number of populations, their frequencies, centres on the original scale and a marker-by-marker plus or minus phenotype from density-valley thresholds.

When to use Automated Flow Cytometry Gating (Gaussian Mixture and Density-Valley Gates)

When to use something else

Assumptions and requirements

What the analysis reports

How to report it

A Gaussian mixture on arcsinh-transformed intensities selected [value] populations by BIC; the largest, [value], accounted for [value]% of events, and [value]% of events fell outside all 95% gates.

Related methods

How this method is validated

이 방법의 검증 근거

  • Independent computation. 1 reference test compares the results with SciPy and direct computations (formulas, enumeration or simulation) at a stated tolerance of 1e-6.

    독립 계산. SciPy·직접 계산(식·열거·모의실험) 대조 참조 시험 1건 통과(허용오차 1e-6).

Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.

허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.

Run Automated Flow Cytometry Gating (Gaussian Mixture and Density-Valley Gates) on Quorant

Data you need
a table (CSV or Excel) with predictor (feature) columns
Price
600 credits for one analysis up to 10,000 rows (complexity level 4); larger or wider data costs more. Optional methodologist review: 2400 credits.
Checking
Compared with independent computations
Before you pay
A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.

Method ID Q98005 · Reviewed 2026-10-25