Generalized Maxwell Spectrum Fitting
Generalized Maxwell spectrum fitting represents storage and loss moduli as a sum of Maxwell relaxation modes with non-negative strengths, yielding a discrete relaxation spectrum and a regularized continuous spectrum.
일반화 Maxwell 스펙트럼 적합은 저장·손실 모듈러스를 음이 아닌 세기를 가진 Maxwell 완화 모드의 합으로 나타내어 이산 완화 스펙트럼과 정칙화된 연속 스펙트럼을 구하는 방법입니다.
How do I get the relaxation time spectrum and zero-shear viscosity from my frequency sweep of G' and G''?
G'와 G'' 주파수 스윕 자료로 완화시간 스펙트럼과 영전단점도를 어떻게 구하나요?
Generalized Maxwell spectrum fitting fits G'(ω) and G''(ω) jointly as sums of Maxwell modes, solving for non-negative mode strengths on a grid of relaxation times and optionally refining the times in log space. A Tikhonov-regularized inversion gives a continuous spectrum H(τ), and the modes give the zero-shear viscosity and steady-state compliance.
When to use Generalized Maxwell Spectrum Fitting
- You have a small-amplitude oscillatory frequency sweep with both G' and G''
- You need relaxation times, a Prony series for simulation, or η0 and Je0
- You want a smooth relaxation spectrum to compare materials
When to use something else
- You measured a step-strain relaxation modulus in time: use Creep, Recovery and Stress Relaxation Model Fitting
- Your sweeps are at several temperatures and not yet superposed: use Time-Temperature Superposition first
Assumptions and requirements
- All data lie in the linear viscoelastic region
- Relative measurement error is similar for G' and G''
- Relaxation times outside the measured frequency window are not determined by the data; sweeps with more than 500 frequencies are thinned evenly to 500 points
What the analysis reports
- Discrete relaxation times and moduli (Prony series)
- Continuous spectrum H(τ) on a log grid with the L-curve regularization parameter
- Zero-shear viscosity, steady-state compliance and mean relaxation time
- RMS log error of the joint fit
How to report it
A generalized Maxwell model with [m] relaxation modes fitted G' and G'' jointly (N = [n] frequencies; RMS log10 error = [value]), giving η0 = [value] Pa·s and Je0 = [value] 1/Pa.
Related methods
- Time-Temperature Superposition
- Creep, Recovery and Stress Relaxation Model Fitting
- Cox-Merz Rule Assessment
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with direct computations (formulas, enumeration or simulation).
독립 계산. 직접 계산(식·열거·모의실험) 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Generalized Maxwell Spectrum Fitting on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- 600 credits for one analysis up to 10,000 rows (complexity level 4); larger or wider data costs more. Optional methodologist review: 2400 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.