Heart Rate Variability Analysis
Heart rate variability analysis quantifies beat-to-beat fluctuation of normal-to-normal heartbeat intervals with time-domain, frequency-domain and nonlinear indices such as SDNN, RMSSD, LF/HF power and Poincaré SD1/SD2.
심박변이도 분석은 정상 심박 간격(NN)의 박동 간 변동을 SDNN, RMSSD, LF/HF 전력, 푸앵카레 SD1/SD2 같은 시간·주파수·비선형 지표로 정량화하는 방법입니다.
I have RR intervals from a 5-minute ECG recording; which HRV measures should I compute and how?
5분 심전도에서 RR 간격을 뽑았는데, 어떤 심박변이도 지표를 어떻게 계산해야 하나요?
Remove artefactual or ectopic beats, then compute time-domain indices (SDNN, RMSSD, pNN50), band powers of the interpolated tachogram in the LF (0.04–0.15 Hz) and HF (0.15–0.4 Hz) bands, and nonlinear indices such as Poincaré SD1/SD2 and short-term DFA alpha1. Report the recording length and how many beats were removed, because both strongly affect the values.
When to use Heart Rate Variability Analysis
- You have RR intervals, R-peak times or a clean ECG from a resting or controlled recording.
- You want standard short-term HRV indices for autonomic research.
- Recordings last at least 2 minutes (5 minutes for VLF).
When to use something else
- The rhythm is not sinus (for example atrial fibrillation) or ectopic beats are frequent; HRV indices are not interpretable there.
- You only have heart rate averaged over minutes; use ordinary time-series summaries instead.
Assumptions and requirements
- The outcome column holds RR intervals (ms or s), R-peak times or a raw ECG, selected with the input option; R peaks in an ECG come from a simple detector and should be checked.
- Intervals are normal sinus beats after artefact screening (beats deviating more than 20% from the local 11-beat median are dropped, not interpolated).
- Approximate stationarity over the analysed segment.
- Sufficient recording length for the frequency bands reported.
What the analysis reports
- SDNN, RMSSD, pNN50 and mean heart rate
- VLF, LF, HF power, LF/HF ratio and LF in normalised units
- Poincaré SD1, SD2 and DFA alpha1
- Number of removed beats
How to report it
Over [value] min, SDNN = [value] ms, RMSSD = [value] ms, LF/HF = [value], SD1/SD2 = [value]/[value] ms and DFA α1 = [value].
Related methods
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with direct computations (formulas, enumeration or simulation).
독립 계산. 직접 계산(식·열거·모의실험) 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Heart Rate Variability Analysis on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.