Interlaboratory Precision Study (ISO 5725-2)
An interlaboratory precision study (ISO 5725-2) estimates the repeatability and reproducibility standard deviations of a measurement method from replicate results reported by several laboratories on the same materials.
실험실 간 정밀도 연구(ISO 5725-2)는 여러 실험실이 같은 시료를 반복 측정한 결과로 측정법의 반복성 표준편차와 재현성 표준편차를 추정하는 방법입니다.
Several labs measured the same samples in replicate; how do I get the repeatability and reproducibility of the method and spot inconsistent labs?
여러 기관이 같은 시료를 반복 측정했는데, 측정법의 반복성·재현성을 구하고 튀는 기관을 찾고 싶어요.
For each material level a one-way random-effects analysis of variance with laboratories as the random factor gives the within-lab (repeatability) variance and the between-lab variance, which together form the reproducibility variance. Mandel's h and k statistics, Cochran's test on variances and Grubbs' test on laboratory means show which laboratories are stragglers or outliers before the limits r = 2.8·s_r and R = 2.8·s_R are reported.
When to use Interlaboratory Precision Study (ISO 5725-2)
- A collaborative trial in which several laboratories measure the same materials with replicates.
- You need repeatability and reproducibility limits for a standard method at several concentration levels.
- You want to check laboratory consistency with Mandel's h and k and outlier tests before pooling.
When to use something else
- Only one laboratory produced the data over several days; use a single-laboratory precision verification (CLSI EP15) or a variance components analysis.
- Laboratories are scored against an assigned value in a proficiency round; use proficiency testing scores (ISO 13528).
Assumptions and requirements
- Laboratory effects and replicate errors are independent and approximately normal.
- Within-laboratory variance is similar across laboratories at a given level.
- Each laboratory reports replicates obtained under repeatability conditions.
What the analysis reports
- s_r, s_L and s_R with r and R limits and CVs for each level
- Mandel h and k for every laboratory with 5% and 1% critical values
- Cochran C and single Grubbs tests with straggler/outlier flags
- Slope of s_r and s_R against the level mean when three or more levels are present
- Optional recalculation without laboratories flagged as outliers
How to report it
At level [value] (p = [value] laboratories, mean = [value]), the repeatability standard deviation was s_r = [value] and the reproducibility standard deviation s_R = [value] (r = [value], R = [value]); [value] laboratories were flagged as outliers by Cochran's or Grubbs' test.
Related methods
- Variance Components Analysis (Random-Effects ANOVA)
- Proficiency Testing Performance Scores (ISO 13528)
- Grubbs' Outlier Test
How this method is validated
이 방법의 검증 근거
- Automated tests. Checked by automated run tests; no external reference comparison is recorded yet.
자동 시험. 자동 실행 시험을 거칩니다. 외부 참조값과 대조한 기록은 아직 없습니다.
Run Interlaboratory Precision Study (ISO 5725-2) on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable, a grouping variable and a cluster ID
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Automated run tests; no external reference comparison yet
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.