Kennard-Stone Calibration Set Selection
Kennard-Stone selection builds a calibration set by starting from the two most distant samples and repeatedly adding the sample farthest from those already chosen, so the set spans the predictor space evenly.
Kennard-Stone 선택은 가장 멀리 떨어진 두 표본에서 시작해 이미 고른 표본과 가장 먼 표본을 차례로 더하여, 예측변수 공간을 고르게 덮는 검량 집합을 만드는 방법입니다.
How should I split 200 spectra into calibration and validation sets so the calibration set covers the whole range of samples?
스펙트럼 200개를 검량용과 검증용으로 나눌 때 검량 집합이 전체 표본 범위를 덮도록 하려면 어떻게 나누나요?
The Kennard-Stone algorithm picks calibration samples that cover the predictor space uniformly, starting from the two most distant spectra and then always adding the one farthest from its nearest selected neighbour; the remaining samples form the validation set inside the calibrated region. The SPXY variant adds the distance in the response so the calibration set also spans the response range.
When to use Kennard-Stone Calibration Set Selection
- Splitting spectra or descriptor data into calibration and validation sets for multivariate calibration or QSAR.
- Choosing which samples to send for expensive reference analysis so that they span the variation.
- Ensuring validation samples lie within the calibration domain.
When to use something else
- An unbiased estimate of performance on future random samples is needed; use a random or stratified split, since Kennard-Stone puts the extremes in calibration.
- Data have more than 10,000 samples; first reduce them by clustering or take a random subsample.
Assumptions and requirements
- The chosen distance (Euclidean on autoscaled or centred data, or Mahalanobis) reflects relevant differences between samples.
- Outliers have been removed, because the algorithm selects extreme samples first.
- For SPXY, the response is available for all samples.
What the analysis reports
- Selection order of calibration samples with the distance at each step (first 60) and the full list of selected rows when there are at most 500
- Calibration and validation sizes (default 75% calibration)
- Largest and mean distance of validation samples to the calibration set
- Distance-at-selection curve
How to report it
The Kennard-Stone algorithm ([value] distance on autoscaled spectra) selected [value] of [value] samples for calibration; the remaining [value] validation samples lay within distance [value] of the calibration set.
Related methods
- Interval PLS Variable Selection (iPLS)
- QSAR Model Validation (OECD Principle 4 Metrics)
- Applicability Domain Assessment
How this method is validated
이 방법의 검증 근거
- Automated tests. Checked by automated run tests; no external reference comparison is recorded yet.
자동 시험. 자동 실행 시험을 거칩니다. 외부 참조값과 대조한 기록은 아직 없습니다.
Run Kennard-Stone Calibration Set Selection on Quorant
- Data you need
- a table (CSV or Excel) with predictor (feature) columns
- Price
- 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Automated run tests; no external reference comparison yet
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.