Laboratory QC with Total Allowable Error and Sigma Metric
Levey–Jennings quality control for a laboratory assay that also uses a 10% total allowable error to compute the sigma metric and pick Westgard rules to match.
총허용오차·시그마 척도를 반영한 검사실 정도관리 — 총허용오차 10%를 넣어 시그마 척도를 계산하고 그에 맞는 Westgard 규칙을 고르는 Levey–Jennings 검사실 정도관리입니다.
Runs Westgard Multirule Laboratory QC (Levey-Jennings) with: tea set to “10”.
기본 방법(Westgard Multirule Laboratory QC (Levey-Jennings))에 다음 설정을 고정해 실행합니다: tea = 10.
Our assay has a 10% allowable total error; how many sigma is it, and which Westgard rules should we run?
총허용오차가 10%인 검사 항목의 시그마 수준과 써야 할 Westgard 규칙을 알고 싶어요.
With the allowable error set, the analysis reports bias, CV, the sigma metric and a rule set sized to that sigma. The entry fixes tea = 10 in Westgard Multirule Laboratory QC (Levey-Jennings); the rest of the output follows Westgard Multirule Laboratory QC (Levey-Jennings).
When to use Laboratory QC with Total Allowable Error and Sigma Metric
- Your regulator or quality goal states the allowable total error as 10%.
- You want rule selection driven by the assay's sigma rather than a fixed multirule set.
When to use something else
- Your analyte has a different allowable error; enter that value in the base QC analysis.
- You want to compare this setting with the alternatives; run Westgard Multirule Laboratory QC (Levey-Jennings) with each option.
What you still provide
- Data: a table (CSV or Excel) with a time variable, an outcome variable and a grouping variable.
Assumptions and requirements
The same as for Westgard Multirule Laboratory QC (Levey-Jennings):
- Control results are approximately normal with the stated target mean and SD.
- Runs are in time order and each control level is identified.
- Pfr and Ped are simulated for one run with one result per level and within-run rules only.
- These are laboratory quality control statistics, not clinical decisions.
What the analysis reports
The output of Westgard Multirule Laboratory QC (Levey-Jennings), with the preset shown in the settings:
- Levey-Jennings z-score chart
- Rule violations and accept, warning or reject decision per run
- Observed mean, SD, bias%, CV% and sigma metric per level
- Probability of false rejection and of error detection at shifts of 1 to 4 SD and at the critical systematic error
How this is validated
검증 근거
This variant runs the same engine as Westgard Multirule Laboratory QC (Levey-Jennings) with the settings above fixed, so the evidence is that method’s: compared with independent computations. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Westgard Multirule Laboratory QC (Levey-Jennings)와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Run this variant
- Data you need
- a table (CSV or Excel) with a time variable, an outcome variable and a grouping variable
- Price
- Same as Westgard Multirule Laboratory QC (Levey-Jennings): 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Compared with independent computations, as recorded for Westgard Multirule Laboratory QC (Levey-Jennings) (see its checks)
- Before you pay