MCP-Mod Dose-Response Analysis
MCP-Mod is a two-step dose-finding analysis that first tests for a dose-response signal with optimal contrasts for several candidate curve shapes and then fits the supported shapes to estimate a target dose.
MCP-Mod는 여러 후보 용량-반응 곡선 모양마다 최적 대비로 용량-반응 신호를 다중성을 통제해 검정한 뒤, 유의한 모양을 적합해 목표 용량을 추정하는 2단계 용량 탐색 분석입니다.
We ran a parallel-group trial with placebo and four doses; how do I test whether there is a dose-response and estimate the dose that gives a clinically relevant effect?
위약과 네 개 용량을 비교한 시험에서 용량-반응이 있는지 검정하고 임상적으로 의미 있는 효과를 내는 용량을 어떻게 추정하나요?
Specify candidate shapes such as linear, Emax, exponential and quadratic with guesstimates before unblinding, compute an optimal contrast for each, and test the largest contrast t statistic against a multivariate t critical value that controls the familywise error. Fit the significant shapes to the dose means, select one by AIC or average them, and report the target dose that reaches the clinically relevant effect over placebo with a bootstrap interval.
When to use MCP-Mod Dose-Response Analysis
- You have a continuous endpoint measured at placebo and at least two active doses in a parallel-group trial.
- You want a multiplicity-controlled test of a dose-response signal that is robust to uncertainty about the curve shape.
- You need a target dose estimate for a pre-specified clinically relevant effect to plan the next phase.
When to use something else
- You only want to compare each dose with placebo; use Dunnett's many-to-one comparisons.
- The endpoint is binary, a count or time to event, or there are repeated measures; use a generalised MCP-Mod with model-based estimates instead of this normal-errors version.
Assumptions and requirements
- Independent normally distributed responses with a common variance across doses.
- Candidate shapes and guesstimates fixed before looking at the data.
- At least three dose levels, two observations per dose, and more dose levels than parameters for any shape that is fitted.
What the analysis reports
- Optimal contrast coefficients and contrast t statistic per candidate shape
- Multiplicity-adjusted one-sided p-values and the multivariate t critical value
- Least-squares parameters and AIC of significant shapes, AIC weights
- Target dose (TD) with a 90% parametric bootstrap interval
- Fitted dose-response curve with pointwise 90% confidence band
How to report it
The MCP step detected a dose-response signal (max t = [value] for the [value] contrast, adjusted p = [value], critical value = [value]); the selected [value] model gave a target dose of [value] mg for an effect of [value] over placebo (90% bootstrap CI [value] to [value]).
Related methods
- Dunnett's Test
- Williams Test for Monotone Dose Trend Against Control
- Nonlinear Least Squares Regression
How this method is validated
이 방법의 검증 근거
- Independent computation. 4 reference tests compare the results with SciPy and direct computations (formulas, enumeration or simulation).
독립 계산. SciPy·직접 계산(식·열거·모의실험) 대조 참조 시험 4건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run MCP-Mod Dose-Response Analysis on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable and a grouping variable
- Price
- 900 credits for one analysis up to 10,000 rows (complexity level 5); larger or wider data costs more. Optional methodologist review: 3600 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.