Model-implied ACF and PACF
Autocorrelations and partial autocorrelations implied by the fitted ARMA with delta-method bands.
모형이 함의하는 자기상관·편자기상관 — 적합한 ARMA가 함의하는 자기상관과 편자기상관을 델타법 구간과 함께 구합니다.
Runs Wold MA(infinity) Representation of an ARMA Model with: implied acf set to “on”.
기본 방법(Wold MA(infinity) Representation of an ARMA Model)에 다음 설정을 고정해 실행합니다: implied acf = on.
What autocorrelation pattern does my fitted ARMA(2,1) imply, and does it match the sample ACF?
적합한 ARMA(2,1)이 함의하는 자기상관 양상은 어떻고, 표본 ACF와 맞나요?
Autocorrelations and partial autocorrelations implied by the fitted ARMA are computed with delta-method bands, so they can be compared with the sample correlogram. Behind it is Wold MA(infinity) Representation of an ARMA Model with implied_acf = true already set; checks and report are the same as for Wold MA(infinity) Representation of an ARMA Model.
When to use Model-implied ACF and PACF
- You want to check whether the fitted model reproduces the observed correlation structure.
- You want to explain the dynamics of the model to readers.
When to use something else
- You only need residual diagnostics; a Ljung–Box test on residuals is more direct.
- You want to try other settings side by side; open Wold MA(infinity) Representation of an ARMA Model and set the options yourself.
What you still provide
- Data: a table (CSV or Excel) with an outcome variable.
Assumptions and requirements
The same as for Wold MA(infinity) Representation of an ARMA Model:
- The series is stationary
- The ARMA orders are adequate
- The moving-average part is invertible for the shocks to be the forecast errors
What the analysis reports
The output of Wold MA(infinity) Representation of an ARMA Model, with the preset shown in the settings:
- psi weights with standard errors and confidence intervals
- Long-run multiplier and half-life
- Forecast error variance and variance share by lag
How this is validated
검증 근거
This variant runs the same engine as Wold MA(infinity) Representation of an ARMA Model with the settings above fixed, so the evidence is that method’s: compared with independent computations. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Wold MA(infinity) Representation of an ARMA Model와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Run this variant
- Data you need
- a table (CSV or Excel) with an outcome variable
- Price
- Same as Wold MA(infinity) Representation of an ARMA Model: 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations, as recorded for Wold MA(infinity) Representation of an ARMA Model (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.