Molecular Weight from Intrinsic Viscosity (Mark–Houwink)
Converts intrinsic viscosity to viscosity-average molecular weight with the Mark–Houwink equation, using the K and a constants you supply for the polymer–solvent pair.
고유 점도에서 구하는 분자량(Mark–Houwink) — 고분자-용매 조합에 맞게 입력한 K와 a 상수로 Mark–Houwink 식을 써서 고유 점도를 점도 평균 분자량으로 바꿉니다.
Runs Intrinsic Viscosity (Huggins and Kraemer) with: .
기본 방법(Intrinsic Viscosity (Huggins and Kraemer))에 다음 설정을 고정해 실행합니다: .
I measured intrinsic viscosity; how do I turn it into a molecular weight?
고유 점도를 측정했는데, 이를 분자량으로 바꾸려면 어떻게 하나요?
With K and a for your polymer, solvent and temperature, the analysis reports Mv alongside [η]. It runs Intrinsic Viscosity (Huggins and Kraemer) with mark_houwink supplied as an extra input; checks and report follow Intrinsic Viscosity (Huggins and Kraemer).
When to use Molecular Weight from Intrinsic Viscosity (Mark–Houwink)
- You have K and a from the literature for the same polymer, solvent and temperature.
- You need molecular weight rather than [η] itself.
When to use something else
- No published constants for your system; the conversion would be guesswork.
- You have nothing to give for mark_houwink; Intrinsic Viscosity (Huggins and Kraemer) runs without it.
What you still provide
- Data: a table (CSV or Excel) with an outcome variable and predictor (feature) columns.
- mark houwink ({'K': 'K', 'a': 'a'})
Assumptions and requirements
The same as for Intrinsic Viscosity (Huggins and Kraemer):
- Measurements are in the dilute regime with relative viscosity roughly between 1.2 and 2
- Solvent viscosity or flow time is measured at the same temperature
- Kinetic energy and density corrections are negligible when flow times are used
What the analysis reports
The output of Intrinsic Viscosity (Huggins and Kraemer), with the preset shown in the settings:
- Intrinsic viscosity from Huggins, Kraemer and a common-intercept fit, each with confidence intervals
- Huggins and Kraemer constants and their difference
- Viscosity-average molar mass when Mark-Houwink constants are supplied
- Huggins plot
How this is validated
검증 근거
This variant runs the same engine as Intrinsic Viscosity (Huggins and Kraemer) with the settings above fixed, so the evidence is that method’s: compared with independent computations. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Intrinsic Viscosity (Huggins and Kraemer)와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Run this variant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- Same as Intrinsic Viscosity (Huggins and Kraemer): 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Compared with independent computations, as recorded for Intrinsic Viscosity (Huggins and Kraemer) (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.