Multivariate Control Chart (Hotelling T² and MEWMA)
A multivariate control chart monitors several correlated quality characteristics jointly, plotting Hotelling's T² or a multivariate EWMA statistic against a control limit and attributing signals to variables.
다변량 관리도는 서로 상관된 여러 품질 특성을 Hotelling T² 또는 다변량 EWMA 통계량 하나로 함께 감시하고, 이상 신호가 어느 변수에서 왔는지 분해해 보여 주는 관리도입니다.
I measure three correlated dimensions on each part; how do I monitor them together instead of with three separate charts, and which variable caused a signal?
부품마다 서로 상관된 치수 세 개를 재는데, 관리도 세 장 대신 한꺼번에 감시하고 신호가 나면 어느 치수 때문인지 알 수 있나요?
Estimate the mean vector and covariance matrix from an in-control phase I sample and plot Hotelling's T² = (x − x̄)ᵀS⁻¹(x − x̄) for each point, using a beta-distribution limit for phase I points and an F limit for new points; a multivariate EWMA smooths the vectors to detect small shifts. When a point signals, the Mason–Tracy–Young decomposition compares unconditional and conditional T² terms to show which variables, alone or given the others, are responsible.
When to use Multivariate Control Chart (Hotelling T² and MEWMA)
- Several quality characteristics are correlated, so separate univariate charts would miss joint shifts or give too many false alarms.
- You have individual observations or rational subgroups of equal size measured over time.
- You need to identify which variables drive an out-of-control point.
When to use something else
- Only one characteristic is monitored; use a Shewhart, CUSUM or EWMA chart.
- The number of variables is close to or larger than the phase I sample size; reduce dimension first (for example with principal components).
Assumptions and requirements
- Observations are independent and approximately multivariate normal when in control.
- The phase I sample is in control and has more points than variables plus one.
- Subgroups (T² chart only; the MEWMA chart uses individual observations) all have the same size of at least two.
What the analysis reports
- Hotelling T² or MEWMA statistic per point with its control limit
- Phase I beta-based and phase II F-based UCL for T²; for MEWMA a limit h simulated for the target in-control ARL or supplied
- Signals with MYT decomposition (unconditional and conditional T² terms and critical values for individuals)
How to report it
A Hotelling T² chart on [value] characteristics ([value] points, α = [value]) signalled at [value] point(s), first at point [value] (T² = [value], UCL = [value]); the MYT decomposition attributed it mainly to [variable] (conditional T² = [value]).
Common variants
자주 쓰는 설정
The same analysis with settings already chosen. Each runs Multivariate Control Chart (Hotelling T² and MEWMA) itself, at the same price.
- Multivariate EWMA Control Chart (MEWMA) — chart set to “mewma”
Related methods
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with reference values computed independently in the test suite.
독립 계산. 시험에서 따로 계산한 참조값 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Multivariate Control Chart (Hotelling T² and MEWMA) on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and predictor (feature) columns
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.