Particle Size Distribution Analysis
Particle size distribution analysis converts sieve masses or cumulative percentages into a cumulative undersize curve, reports D10, D50, D90 and span, and fits log-normal, Rosin-Rammler and Gaudin-Schuhmann models.
입도 분포 분석은 체 질량이나 누적 백분율을 누적 통과율 곡선으로 바꾸어 D10·D50·D90과 스팬을 구하고 로그정규·Rosin-Rammler·Gaudin-Schuhmann 모형을 적합하는 방법입니다.
From my sieve analysis masses, what are the D10, D50 and D90 of this powder, and does it follow a log-normal distribution?
체 분석 질량 자료로 이 분말의 D10, D50, D90을 구하고 로그정규분포를 따르는지 알고 싶어요.
Masses retained on each sieve are turned into cumulative percent undersize, and D-values are read by interpolating log size against the cumulative fraction. Linearised fits of the log-normal (probit), Rosin-Rammler and Gaudin-Schuhmann models give their parameters and R-squared, so the span, geometric standard deviation and model fit can be reported.
When to use Particle Size Distribution Analysis
- You have sieve masses per aperture or laser-diffraction cumulative percent undersize.
- You need D10, D50, D90 and span for a specification or report.
- You want to know which distribution model describes the powder.
When to use something else
- You have particle counts for single particles; summarise them with descriptive statistics or fit a distribution directly instead.
- You need to compare distributions between batches statistically; use a two-sample test on the size data or an equivalence approach instead.
Assumptions and requirements
- Each size appears once; the pan is entered with size 0.
- Cumulative undersize increases with size.
- Log-linear interpolation between measured sizes is adequate.
- D-values outside the measured range are taken from the best-fitting model.
What the analysis reports
- D10, D50, D90 and span
- Geometric mean size and geometric SD
- Model parameters for log-normal, Rosin-Rammler and Gaudin-Schuhmann
- R-squared on the linearised and cumulative scales
How to report it
The particle size distribution had D10 = [value] µm, D50 = [value] µm and D90 = [value] µm (span = [value]); the log-normal model fitted with R2 = [value] (geometric SD = [value]).
Related methods
- Distribution Fitting and Selection by Maximum Likelihood
- Drug Release Kinetics Model Fitting
- Simple Linear Regression
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with direct computations (formulas, enumeration or simulation).
독립 계산. 직접 계산(식·열거·모의실험) 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Particle Size Distribution Analysis on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.