Power Spectral Density by Multitaper (Slepian Tapers)
Estimates the power spectral density by Thomson's multitaper method, averaging periodograms from several orthogonal Slepian tapers to cut variance without much leakage.
다중 테이퍼 전력 스펙트럼 밀도(Slepian 테이퍼) — 직교하는 Slepian 테이퍼 여러 개의 주기도를 평균해 누설을 크게 늘리지 않고 분산을 줄이는 Thomson 다중 테이퍼 방법으로 전력 스펙트럼 밀도를 추정합니다.
Runs Welch and Multitaper Power Spectral Density with: method set to “multitaper”.
기본 방법(Welch and Multitaper Power Spectral Density)에 다음 설정을 고정해 실행합니다: method = multitaper.
My record is short and the Welch spectrum is too noisy; how do I get a more stable spectrum?
기록이 짧아 Welch 스펙트럼이 너무 들쭉날쭉한데, 더 안정된 스펙트럼을 얻으려면?
Multitaper estimation averages several tapered spectra of the whole record instead of splitting it into segments. It is Welch and Multitaper Power Spectral Density run with method = multitaper, so the output carries the same diagnostics and report layout.
When to use Power Spectral Density by Multitaper (Slepian Tapers)
- The record is short, so Welch segments would be too few or too short.
- You need low leakage near strong spectral peaks.
When to use something else
- The record is long and stationary; Welch averaging is simpler and adequate.
- You need a different value for method; use Welch and Multitaper Power Spectral Density directly.
What you still provide
- Data: a table (CSV or Excel) with a time variable and an outcome variable.
Assumptions and requirements
The same as for Welch and Multitaper Power Spectral Density:
- The signal is approximately stationary over the record.
- Samples are equally spaced at a known sampling frequency.
- The chi-square interval assumes approximately Gaussian data.
What the analysis reports
The output of Welch and Multitaper Power Spectral Density, with the preset shown in the settings:
- One-sided power spectral density with chi-square confidence band (up to 60 frequencies in the table)
- Equivalent degrees of freedom and frequency resolution
- Top dominant frequencies and their PSD
- Total power and band power (absolute and percent) for user bands
How this is validated
검증 근거
This variant runs the same engine as Welch and Multitaper Power Spectral Density with the settings above fixed, so the evidence is that method’s: automated run tests; no external reference comparison yet. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Welch and Multitaper Power Spectral Density와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Run this variant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- Same as Welch and Multitaper Power Spectral Density: 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Automated run tests; no external reference comparison yet, as recorded for Welch and Multitaper Power Spectral Density (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.