Quantal Dose-Response Analysis (Probit/Logit ED50)
Quantal dose-response analysis (probit/logit) models the proportion of subjects responding at each dose with a binomial model on log dose to estimate effective or lethal doses such as the ED50 with Fieller limits.
양자 반응 용량–반응 분석(프로빗·로짓)은 용량별 반응 개체 비율을 로그 용량에 대한 이항 모형으로 맞춰 ED50 같은 유효·치사 용량을 Fieller 한계와 함께 추정하는 방법입니다.
Also known as: Quantal Dose–Response (Probit)
다른 이름: 계수형 용량-반응(프로빗)
Groups of 20 insects were exposed to six insecticide concentrations and I counted the dead; what are the LD50 and LD90 with confidence limits?
곤충 20마리씩을 살충제 여섯 가지 농도에 노출하고 죽은 수를 셌는데, LD50 과 LD90 및 신뢰한계는 얼마인가요?
A binomial model with probit, logit or complementary log-log link is fitted on log10 dose by Fisher scoring, and the dose giving response probability p is ED_p = (g(p) − a)/b with Fieller confidence limits back-transformed to the dose scale. A Pearson heterogeneity chi-square checks fit; when it is significant the covariance is inflated by χ²/df and t quantiles are used, and an optional Abbott correction accounts for a natural response rate in controls.
When to use Quantal Dose-Response Analysis (Probit/Logit ED50)
- Each row is a dose group with the dose, the number tested and the number responding (dead, affected, positive).
- You need ED50, LD50 or other ED_p values with Fieller confidence limits.
- Control groups show some natural response that should be corrected for (Abbott).
When to use something else
- The response is a continuous measurement; use Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50).
- You have individual-level data with several predictors beyond dose; use Probit Regression Model or Binary Logistic Regression.
Assumptions and requirements
- At least three distinct positive dose levels; zero-dose controls are excluded from the log-dose fit and used only for Abbott correction.
- Subjects respond independently within a dose group; extra-binomial variation is handled by the heterogeneity factor.
- The slope is precise enough for bounded Fieller limits (g < 1; g < 0.05 for delta-method intervals to be trusted).
- With Abbott correction, the control response rate C is treated as fixed, so its uncertainty is not in the intervals.
What the analysis reports
- Intercept and slope on the link scale with SE and z
- ED_p for each requested p (default 0.5, 0.1, 0.9) with Fieller limits and delta-method SE on the log-dose scale
- Heterogeneity chi-square, df, p and inflation factor; Fieller g
- Plot of empirical link-scale response against log10 dose
How to report it
A probit model on log10 concentration ([value] dose groups, N = [value]) gave slope = [value] (SE = [value]); heterogeneity χ²([value]) = [value], p = [value]. The estimated LD50 was [value] mg/L (95% Fieller limits [value] to [value]).
Common variants
자주 쓰는 설정
The same analysis with settings already chosen. Each runs Quantal Dose-Response Analysis (Probit/Logit ED50) itself, at the same price.
- Quantal Dose–Response (Logit) — link set to “logit”
- Probit analysis with estimated natural response — abbott set to “ml”
- Probit analysis with deviance goodness of fit — deviance set to “on”
- Parallel-line probit assay —
Related methods
- Probit Regression Model
- Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50)
- Microbial Dose-Response Model (Exponential, Beta-Poisson)
How this method is validated
이 방법의 검증 근거
- Automated tests. Checked by automated run tests; no external reference comparison is recorded yet.
자동 시험. 자동 실행 시험을 거칩니다. 외부 참조값과 대조한 기록은 아직 없습니다.
Run Quantal Dose-Response Analysis (Probit/Logit ED50) on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable, predictor (feature) columns and a weight column
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Automated run tests; no external reference comparison yet
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.