Thermal Cycling Acceleration Factor (Coffin–Manson)
Thermal cycling acceleration factor from the Coffin–Manson power law on temperature swing.
온도 순환 가속 계수(Coffin–Manson) — 온도 변동폭에 대한 Coffin–Manson 거듭제곱 법칙으로 온도 순환 가속 계수를 구합니다.
Runs Acceleration factor calculator with: model set to “coffin_manson”.
기본 방법(Acceleration factor calculator)에 다음 설정을 고정해 실행합니다: model = coffin_manson.
Our test cycles span 165°C versus 40°C in the field; how much faster is fatigue?
시험 순환 폭이 165°C이고 현장은 40°C인데, 피로가 몇 배 빠른가요?
AF = (ΔTtest/ΔTuse)^n for low-cycle fatigue. Behind it is the Acceleration factor calculator with model = coffin_manson set; the other inputs work as usual.
When to use Thermal Cycling Acceleration Factor (Coffin–Manson)
- Fatigue from temperature cycling.
- Known exponent for the material.
When to use something else
- Frequency and peak temperature also matter; use Norris–Landzberg.
- You need a different value for model; use the Acceleration factor calculator directly.
What you still provide
- Data: the summary numbers the calculator asks for; no data file.
How this is validated
검증 근거
This preset fills in settings of the Acceleration factor calculator; the calculation is that calculator’s. No separate checks of this preset are claimed.
이 설정 묶음은 Acceleration factor calculator의 설정을 채워 둔 것입니다. 계산은 그 계산기와 같으며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Other variants of Acceleration factor calculator
- Temperature–Humidity Acceleration Factor (Peck)
- Acceleration Factor (Eyring Model)
- Thermal Acceleration Factor (Arrhenius)
- Solder-Joint Cycling Acceleration Factor (Norris–Landzberg)
Run this variant
- Data you need
- the summary numbers the calculator asks for; no data file
- Price
- Free in the browser calculator; no credits are used.
- Checking
- Uses the same calculator as the Acceleration factor calculator; no separate validation record is published for this preset.