Weak-Instrument-Robust Inference (Conditional LR)
Weak-instrument-robust inference with Moreira's conditional likelihood ratio test and confidence set.
약한 도구 강건 추론(조건부 LR) — Moreira의 조건부 우도비 검정과 신뢰 집합으로 약한 도구에도 유효한 추론을 합니다.
Runs Weak Instrument Diagnostics and LIML with: clr set to “on”.
기본 방법(Weak Instrument Diagnostics and LIML)에 다음 설정을 고정해 실행합니다: clr = on.
My first-stage F is low; how do I get valid inference on the IV coefficient?
1단계 F가 낮은데, 도구변수 계수에 유효한 추론을 하려면?
The CLR test has correct size regardless of instrument strength. Behind it is Weak Instrument Diagnostics and LIML with clr = true already set; checks and report are the same as for Weak Instrument Diagnostics and LIML.
When to use Weak-Instrument-Robust Inference (Conditional LR)
- Instruments may be weak.
- A single endogenous regressor.
When to use something else
- Several endogenous regressors; CLR sets are harder to compute.
- You want to try other settings side by side; open Weak Instrument Diagnostics and LIML and set the options yourself.
What you still provide
- Data: a table (CSV or Excel) with an outcome variable and predictor (feature) columns.
Assumptions and requirements
The same as for Weak Instrument Diagnostics and LIML:
- Instruments satisfy exclusion and independence.
- Linear first-stage and structural equations.
- Robust and clustered versions assume independence across observations or clusters.
What the analysis reports
The output of Weak Instrument Diagnostics and LIML, with the preset shown in the settings:
- Classical first-stage F, robust F (equal to Kleibergen-Paap rk Wald F for one endogenous regressor), effective F and partial R²
- Cragg-Donald statistic when there are several endogenous regressors
- LIML, Fuller-k and 2SLS estimates with SEs and the LIML kappa
- Anderson-Rubin test of no effect and its confidence set (one endogenous regressor)
- Optional conditional likelihood-ratio (CLR) test of no effect and its inverted confidence set (one endogenous regressor, homoskedastic form)
How this is validated
검증 근거
This variant runs the same engine as Weak Instrument Diagnostics and LIML with the settings above fixed, so the evidence is that method’s: compared with independent computations. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Weak Instrument Diagnostics and LIML와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Other variants of Weak Instrument Diagnostics and LIML
Run this variant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- Same as Weak Instrument Diagnostics and LIML: 600 credits for one analysis up to 10,000 rows (complexity level 4); larger or wider data costs more. Optional methodologist review: 2400 credits.
- Checking
- Compared with independent computations, as recorded for Weak Instrument Diagnostics and LIML (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.