Adaptive and Wiener Filtering
Adaptive and Wiener filtering cancels noise by passing a reference noise signal through FIR weights updated by LMS, NLMS or RLS (or a Wiener transfer function) and subtracting the estimate from the primary signal.
적응·위너 필터링은 참조 잡음 신호를 LMS·NLMS·RLS로 갱신되는 FIR 가중치(또는 위너 전달함수)로 걸러 주신호에서 빼어 원래 신호를 되찾는 방법입니다.
I have a measurement contaminated by noise and a separate sensor that records only the noise source; how can I cancel the noise?
측정 신호에 잡음이 섞였는데 잡음원만 따로 기록한 센서가 있습니다. 잡음을 어떻게 제거하나요?
Use the noise-only sensor as the reference input of an adaptive FIR filter whose weights are updated by LMS, NLMS or RLS to minimise the output power; the filter error is the cleaned signal. A non-causal Wiener filter estimated from the cross-spectrum gives the offline optimum for stationary data.
When to use Adaptive and Wiener Filtering
- A reference signal correlated with the noise but not with the wanted signal is available.
- The noise path may change slowly over time (adaptive methods).
- You want an offline benchmark of the best linear cancellation (Wiener).
When to use something else
- No reference noise signal exists; use ordinary filtering or spectral subtraction.
- The reference also contains the wanted signal; the canceller will remove part of the signal, so use a source separation method.
Assumptions and requirements
- The primary signal (signal plus noise) is the outcome and the noise reference is the first feature column; adaptive methods analyse at most 50,000 samples.
- Noise in the primary signal is a linear (FIR) function of the reference.
- The reference is uncorrelated with the wanted signal.
- Step size or forgetting factor is in the stable range.
What the analysis reports
- Cleaned (error) signal and learning curve
- Weight trajectory and final weights versus the Wiener–Hopf solution
- Noise reduction in dB, or SNR improvement when a clean signal is supplied
- Wiener transfer function (Wiener method)
How to report it
An NLMS canceller ([value] taps, μ = [value]) reduced output variance by [value] dB and improved the SNR by [value] dB.
Common variants
자주 쓰는 설정
The same analysis with settings already chosen. Each runs Adaptive and Wiener Filtering itself, at the same price.
- Adaptive Filtering by Least Mean Squares — method set to “lms”
- Adaptive Filtering by Recursive Least Squares — method set to “rls”
- Noise Reduction by Wiener Filtering — method set to “wiener”
Related methods
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with reference values computed independently in the test suite.
독립 계산. 시험에서 따로 계산한 참조값 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Adaptive and Wiener Filtering on Quorant
- Data you need
- a table (CSV or Excel) with a time variable, an outcome variable and predictor (feature) columns
- Price
- 600 credits for one analysis up to 10,000 rows (complexity level 4); larger or wider data costs more. Optional methodologist review: 2400 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.