Anderson-Hauck bioequivalence test
Single test of non-equivalence against both acceptance limits using a shifted central t distribution.
Anderson-Hauck 생물학적 동등성 검정 — 양쪽 허용 한계에 대한 비동등성을 이동된 중심 t분포로 한 번에 검정합니다.
Runs Average Bioequivalence Analysis with: anderson hauck set to “on”.
기본 방법(Average Bioequivalence Analysis)에 다음 설정을 고정해 실행합니다: anderson hauck = on.
Instead of two one-sided tests, can I get one p-value for bioequivalence?
두 번의 단측 검정 대신 생물학적 동등성에 대한 p값 하나를 얻을 수 있나요?
The Anderson-Hauck test gives a single p-value for the null of non-equivalence against both limits; it is somewhat more powerful than TOST but its size can exceed the nominal level. Behind it is Average Bioequivalence Analysis with anderson_hauck = true already set; checks and report are the same as for Average Bioequivalence Analysis.
When to use Anderson-Hauck bioequivalence test
- You want a single p-value to supplement TOST.
- Small studies where TOST is conservative.
When to use something else
- Regulatory submission requires TOST or the 90% interval; use those.
- You want to try other settings side by side; open Average Bioequivalence Analysis and set the options yourself.
What you still provide
- Data: a table (CSV or Excel) with an outcome variable, a unit (entity) ID, a time variable, a treatment indicator and a grouping variable.
Assumptions and requirements
The same as for Average Bioequivalence Analysis:
- Log-transformed PK parameters are approximately normal with constant within-subject variance.
- No unequal carryover between periods (adequate washout).
- Subjects are independent and the treatment sequence was randomised.
What the analysis reports
The output of Average Bioequivalence Analysis, with the preset shown in the settings:
- Geometric mean ratio (T/R) with 90% confidence interval and bioequivalence decision
- Within-subject CV, period F test and sequence test against between-subject variation
- For replicate designs: s_wR and CVwR with EMA widened limits or the FDA linearised criterion upper bound (Howe method)
How this is validated
검증 근거
This variant runs the same engine as Average Bioequivalence Analysis with the settings above fixed, so the evidence is that method’s: automated run tests; no external reference comparison yet. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Average Bioequivalence Analysis와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Other variants of Average Bioequivalence Analysis
Run this variant
- Data you need
- a table (CSV or Excel) with an outcome variable, a unit (entity) ID, a time variable, a treatment indicator and a grouping variable
- Price
- Same as Average Bioequivalence Analysis: 600 credits for one analysis up to 10,000 rows (complexity level 4); larger or wider data costs more. Optional methodologist review: 2400 credits.
- Checking
- Automated run tests; no external reference comparison yet, as recorded for Average Bioequivalence Analysis (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.