Westlake symmetric confidence interval
Bioequivalence interval for the test/reference ratio placed symmetrically about one on the log scale.
Westlake 대칭 신뢰구간 — 로그 척도에서 비율 1을 중심으로 대칭이 되도록 시험약/대조약 비의 생물학적 동등성 구간을 잡습니다.
Runs Average Bioequivalence Analysis with: westlake set to “on”.
기본 방법(Average Bioequivalence Analysis)에 다음 설정을 고정해 실행합니다: westlake = on.
The regulator asks for Westlake's symmetric interval for the test/reference ratio; how do I compute it?
규제 기관이 시험약/대조약 비에 대한 Westlake 대칭 구간을 요구하는데, 어떻게 계산하나요?
The interval is placed symmetrically about a ratio of one on the log scale and has the stated coverage, so equivalence is shown when it lies within the acceptance limits. Behind it is Average Bioequivalence Analysis with westlake = true already set; checks and report are the same as for Average Bioequivalence Analysis.
When to use Westlake symmetric confidence interval
- A reviewer or older guideline asks for the Westlake interval.
- You want to compare it with the usual 90% interval.
When to use something else
- Current guidelines accept the conventional 90% interval or TOST; report that as the primary result.
- You want to try other settings side by side; open Average Bioequivalence Analysis and set the options yourself.
What you still provide
- Data: a table (CSV or Excel) with an outcome variable, a unit (entity) ID, a time variable, a treatment indicator and a grouping variable.
Assumptions and requirements
The same as for Average Bioequivalence Analysis:
- Log-transformed PK parameters are approximately normal with constant within-subject variance.
- No unequal carryover between periods (adequate washout).
- Subjects are independent and the treatment sequence was randomised.
What the analysis reports
The output of Average Bioequivalence Analysis, with the preset shown in the settings:
- Geometric mean ratio (T/R) with 90% confidence interval and bioequivalence decision
- Within-subject CV, period F test and sequence test against between-subject variation
- For replicate designs: s_wR and CVwR with EMA widened limits or the FDA linearised criterion upper bound (Howe method)
How this is validated
검증 근거
This variant runs the same engine as Average Bioequivalence Analysis with the settings above fixed, so the evidence is that method’s: automated run tests; no external reference comparison yet. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Average Bioequivalence Analysis와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Other variants of Average Bioequivalence Analysis
Run this variant
- Data you need
- a table (CSV or Excel) with an outcome variable, a unit (entity) ID, a time variable, a treatment indicator and a grouping variable
- Price
- Same as Average Bioequivalence Analysis: 600 credits for one analysis up to 10,000 rows (complexity level 4); larger or wider data costs more. Optional methodologist review: 2400 credits.
- Checking
- Automated run tests; no external reference comparison yet, as recorded for Average Bioequivalence Analysis (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.