Benchmark Dose Analysis (BMD and BMDL)
Benchmark dose analysis fits a set of dose-response models and estimates the dose producing a predefined change in response (BMD) with its lower confidence limit (BMDL) for use as a point of departure.
기준 용량 분석은 여러 용량-반응 모형을 맞춰 정해진 반응 변화를 일으키는 용량(BMD)과 그 하한 신뢰한계(BMDL)를 출발점으로 추정하는 방법입니다.
What dose causes a 10% extra risk of the adverse effect, and what is its lower confidence bound?
이 독성 영향의 추가 위험이 10%가 되는 용량과 그 하한 신뢰한계가 얼마인지 알고 싶어요.
Quantal models (logistic, probit, log-logistic, log-probit, Weibull, gamma, multistage, quantal-linear) or continuous models (linear, power, exponential, Hill) are fitted by maximum likelihood, and the BMD solves extra risk = BMR or a mean change of BMR standard deviations. The BMDL and BMDU come from the profile likelihood with the model reparameterized by the BMD, and models are compared by goodness of fit, AIC and an AIC-weighted average curve.
When to use Benchmark Dose Analysis (BMD and BMDL)
- You have dose groups with quantal incidence or continuous responses
- You need a point of departure for risk assessment instead of a NOAEL
- You want to compare several dose-response models
When to use something else
- You need an ED50 with a single model: use Quantal Dose-Response Analysis (Probit/Logit ED50)
- You compare doses only with a control by pairwise tests: use the Williams Test for Monotone Dose Trend Against Control
Assumptions and requirements
- Binomial responses (quantal) or normal responses with constant variance (continuous)
- At least three dose groups with a monotone trend
- The chosen BMR is meaningful for the endpoint
What the analysis reports
- BMD, BMDL and BMDU by model
- AIC, AIC weights and goodness-of-fit p by model
- Selected model under the EPA rule
- Model-average BMD (no model-average BMDL)
How to report it
Benchmark dose modelling (BMR = 10% extra risk) selected the [model] model (goodness-of-fit p = [value]), giving BMD = [value] and BMDL = [value] [units].
Related methods
- Quantal Dose-Response Analysis (Probit/Logit ED50)
- Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50)
- Microbial Dose-Response Model (Exponential, Beta-Poisson)
How this method is validated
이 방법의 검증 근거
- Automated tests. Checked by automated run tests; no external reference comparison is recorded yet.
자동 시험. 자동 실행 시험을 거칩니다. 외부 참조값과 대조한 기록은 아직 없습니다.
Run Benchmark Dose Analysis (BMD and BMDL) on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- 600 credits for one analysis up to 10,000 rows (complexity level 4); larger or wider data costs more. Optional methodologist review: 2400 credits.
- Checking
- Automated run tests; no external reference comparison yet
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.