Dose–Response Fit (Emax)
Fits the hyperbolic Emax model, effect = E0 + Emax·dose/(ED50 + dose).
용량-반응 적합(Emax) — 효과 = E0 + Emax·용량/(ED50 + 용량)인 쌍곡 Emax 모형을 적합합니다.
Runs Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) with: model set to “emax”.
기본 방법(Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50))에 다음 설정을 고정해 실행합니다: model = emax.
Which simple dose–response model is used in dose-finding trials?
용량 탐색 임상에서 쓰는 단순 용량-반응 모형은?
The Emax model has three parameters and a Hill slope of one. Technically this is Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) with model = emax fixed; nothing else about the analysis changes.
When to use Dose–Response Fit (Emax)
- Clinical dose-finding.
- A plateau is expected.
When to use something else
- Steep curves; the sigmoid Emax adds a Hill coefficient.
- You would rather keep every option open; Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) gives you the full set.
What you still provide
- Data: a table (CSV or Excel) with an outcome variable and predictor (feature) columns.
Assumptions and requirements
The same as for Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50):
- Doses are non-negative (zero dose is allowed as a control) and the tested range covers both plateaus; an EC50 outside the range is flagged as extrapolation.
- Residuals are independent, roughly normal and of constant variance (checked by Spearman correlation of |residuals| with fitted values).
- For relative potency, the curves are parallel (common bottom, top and Hill slope).
What the analysis reports
The output of Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50), with the preset shown in the settings:
- Parameter table (bottom, top, log10 EC50, Hill slope, asymmetry for 5PL) with SE and Wald CIs, plus EC50 with back-transformed CI
- Residual SE, R², AIC and, for 5PL, the dose at half-maximal response
- With groups: separate and parallel EC50 per group, F test of parallelism, relative potency with 95% CI
- Plot of response against log10 dose
- Optional linear bioassays in the Ph. Eur. 5.3 layout (assay='parallel_line' or 'slope_ratio'): analysis of variance with preparations, regression, non-parallelism or intersection, blanks and non-linearity, a validity verdict, and relative potency with Fieller 95% limits
How this is validated
검증 근거
This variant runs the same engine as Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) with the settings above fixed, so the evidence is that method’s: automated run tests; no external reference comparison yet. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50)와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Other variants of Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50)
- Dose–Response Fit (Three-Parameter Logistic)
- Relative Potency by Slope-Ratio Assay
- Relative Potency by Parallel-Line Assay
- Robust dose-response curve fitting
- ECx at chosen effect levels
Run this variant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- Same as Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50): 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Automated run tests; no external reference comparison yet, as recorded for Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.