Dose–Response Fit (Three-Parameter Logistic)
Fits a three-parameter logistic dose–response curve with one asymptote fixed (often the bottom at zero).
용량-반응 적합(3모수 로지스틱) — 한쪽 점근선(흔히 바닥 0)을 고정한 3모수 로지스틱 용량-반응 곡선을 적합합니다.
Runs Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) with: model set to “3pl”.
기본 방법(Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50))에 다음 설정을 고정해 실행합니다: model = 3pl.
My response starts at zero by design; how do I fit EC50 with that constraint?
반응이 설계상 0에서 시작하는데, 그 제약을 두고 EC50을 적합하려면?
Fixing one asymptote leaves top, slope and EC50 to estimate. Behind it is Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) with model = 3pl already set; checks and report are the same as for Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50).
When to use Dose–Response Fit (Three-Parameter Logistic)
- One asymptote is known from the assay.
- Too few points at one end to estimate it.
When to use something else
- Both asymptotes vary; use the 4PL.
- You want to try other settings side by side; open Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) and set the options yourself.
What you still provide
- Data: a table (CSV or Excel) with an outcome variable and predictor (feature) columns.
Assumptions and requirements
The same as for Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50):
- Doses are non-negative (zero dose is allowed as a control) and the tested range covers both plateaus; an EC50 outside the range is flagged as extrapolation.
- Residuals are independent, roughly normal and of constant variance (checked by Spearman correlation of |residuals| with fitted values).
- For relative potency, the curves are parallel (common bottom, top and Hill slope).
What the analysis reports
The output of Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50), with the preset shown in the settings:
- Parameter table (bottom, top, log10 EC50, Hill slope, asymmetry for 5PL) with SE and Wald CIs, plus EC50 with back-transformed CI
- Residual SE, R², AIC and, for 5PL, the dose at half-maximal response
- With groups: separate and parallel EC50 per group, F test of parallelism, relative potency with 95% CI
- Plot of response against log10 dose
- Optional linear bioassays in the Ph. Eur. 5.3 layout (assay='parallel_line' or 'slope_ratio'): analysis of variance with preparations, regression, non-parallelism or intersection, blanks and non-linearity, a validity verdict, and relative potency with Fieller 95% limits
How this is validated
검증 근거
This variant runs the same engine as Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) with the settings above fixed, so the evidence is that method’s: automated run tests; no external reference comparison yet. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50)와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Other variants of Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50)
- Dose–Response Fit (Emax)
- Relative Potency by Slope-Ratio Assay
- Relative Potency by Parallel-Line Assay
- Robust dose-response curve fitting
- ECx at chosen effect levels
Run this variant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- Same as Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50): 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Automated run tests; no external reference comparison yet, as recorded for Dose-Response Curve Fitting (4PL / Sigmoid Emax, EC50) (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.