Event-Locked Ensemble and Time-Synchronous Averaging
Event-locked ensemble averaging cuts a signal into epochs aligned to repeated events and averages them, or resamples each shaft revolution to a fixed angle grid (time-synchronous averaging), so that random noise cancels.
사건 고정 앙상블 평균은 반복되는 사건에 맞춰 신호를 구간으로 잘라 평균하거나, 회전마다 일정한 각도 격자로 다시 표본화해 평균(시간 동기 평균)함으로써 무작위 잡음을 상쇄하는 방법입니다.
I have a noisy recording with event markers; how do I extract the average evoked response and quantify how much averaging improved the signal-to-noise ratio?
사건 표시가 있는 잡음 많은 기록에서 평균 유발 반응을 뽑고, 평균으로 신호대잡음비가 얼마나 좋아졌는지 어떻게 알 수 있나요?
Cut epochs around each event, subtract the pre-event baseline, reject epochs above an amplitude threshold and average, with pointwise confidence bands. Estimate the residual noise from the plus-minus average and report the SNR per trial and after averaging, the peak latency and amplitude, or for rotating machines the time-synchronous average and its residual.
When to use Event-Locked Ensemble and Time-Synchronous Averaging
- You have repeated stimulus or trigger events and want the event-related response.
- You need the number of accepted epochs and the SNR gain from averaging.
- You have a tachometer signal and want the time-synchronous average of a gear or shaft vibration and the residual for fault detection.
When to use something else
- The response varies in latency from trial to trial; use single-trial methods or time-frequency analysis.
- There are no repeated events; use spectral estimation or filtering.
Assumptions and requirements
- Sampling is even; event times map to the nearest sample.
- The response is the same on every epoch and the noise is independent of the events.
- For time-synchronous averaging, speed is nearly constant within a revolution.
What the analysis reports
- Averaged waveform with pointwise t confidence bands
- Number of events, accepted, rejected and edge-skipped epochs
- Plus-minus noise estimate and SNR per trial and after averaging
- Peak latency and amplitude, or TSA, residual RMS and kurtosis
How to report it
Averaging [value] of [value] event-locked epochs ([value] to [value] s) gave a peak of [value] uV at [value] ms; the SNR rose from [value] dB per trial to [value] dB after averaging.
Common variants
자주 쓰는 설정
The same analysis with settings already chosen. Each runs Event-Locked Ensemble and Time-Synchronous Averaging itself, at the same price.
Related methods
- Time-Domain Signal Features (RMS, Crest Factor, Kurtosis)
- Adaptive and Wiener Filtering
- Welch and Multitaper Power Spectral Density
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with direct computations (formulas, enumeration or simulation).
독립 계산. 직접 계산(식·열거·모의실험) 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Event-Locked Ensemble and Time-Synchronous Averaging on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.