Flow Duration Curve and Low-Flow Frequency (7Q10)
Flow duration and low-flow frequency analysis ranks daily flows into exceedance percentiles and fits a distribution to annual minima of n-day mean flows to estimate design low flows such as the 7Q10.
유량지속곡선과 저유량 빈도분석은 일유량을 초과확률 백분위로 정렬하고 n일 평균유량의 연최소값에 분포를 적합해 7Q10 같은 설계 저유량을 추정합니다.
Also known as: Seven-Day Ten-Year Low Flow (7Q10)
다른 이름: 7일 10년 갈수량(7Q10)
From 20 years of daily streamflow, how do I compute the flow duration curve, Q95 and the 7Q10 low flow for a discharge permit?
20년치 일유량 자료로 유량지속곡선, Q95, 그리고 방류 허가용 7Q10 저유량을 어떻게 계산하나요?
Rank all daily flows with Weibull plotting positions to read flows exceeded 90% and 95% of the time, then take the minimum 7-day moving average in each climatic year starting in April. Fit a log-Pearson type III distribution by moments of the log minima and read the flow with a 10% annual non-exceedance probability as the 7Q10.
When to use Flow Duration Curve and Low-Flow Frequency (7Q10)
- You need design low flows (7Q10, 30Q5) for water quality permits or abstraction limits.
- You want to characterise flow regime with flow duration percentiles such as Q90 and Q95.
- You have a daily discharge record of at least several complete years.
When to use something else
- You need flood quantiles from annual peaks; use flood frequency analysis.
- The record has strong trends or regulation changes; test and model nonstationarity first (e.g. Mann-Kendall trend test).
Assumptions and requirements
- Daily flows with calendar dates; climatic years with any missing day are dropped (at least 5 complete years).
- Annual minima are independent and stationary.
- Zero-flow years are handled with the conditional probability adjustment.
What the analysis reports
- Flow duration quantiles with Q50, Q90 and Q95
- Annual n-day minima by climatic year
- nQT low-flow quantile (7Q10 by default) with fitted parameters
- Probability-plot correlation of the fitted distribution
How to report it
Daily flows for [years] gave Q95 = [value] m3/s; a log-Pearson III fit to [value] annual 7-day minima (climatic years beginning 1 April) gave 7Q10 = [value] m3/s (PPCC = [value]).
Related methods
- Flood Frequency Analysis (Log-Pearson III and L-Moments)
- Baseflow Separation (Lyne-Hollick and Eckhardt Filters)
- Mann-Kendall Trend Test with Sen's Slope
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with reference values computed independently in the test suite.
독립 계산. 시험에서 따로 계산한 참조값 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Flow Duration Curve and Low-Flow Frequency (7Q10) on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.