Baseflow Separation (Lyne-Hollick and Eckhardt Filters)
Baseflow separation splits a streamflow hydrograph into slow baseflow and quickflow with recursive digital filters such as the Lyne-Hollick and Eckhardt filters and summarises it by the baseflow index.
기저유출 분리는 Lyne-Hollick, Eckhardt 같은 재귀 디지털 필터로 유량 수문곡선을 느린 기저유출과 빠른 직접유출로 나누고 기저유출지수로 요약합니다.
How much of my river's daily flow comes from groundwater baseflow, and how do I compute the baseflow index?
하천 일유량 중 지하수 기저유출이 차지하는 비율은 얼마이고 기저유출지수는 어떻게 계산하나요?
Apply the Lyne-Hollick filter with alpha = 0.925 in three alternating passes and the Eckhardt two-parameter filter with a recession constant and a maximum baseflow index suited to the aquifer. The baseflow index is total baseflow divided by total streamflow, and comparing the two filters shows how sensitive the result is to the filter choice.
When to use Baseflow Separation (Lyne-Hollick and Eckhardt Filters)
- You want the baseflow index of a catchment from a daily flow record.
- You need a baseflow series for groundwater recharge or low-flow studies.
- You want to compare catchments by their slow-flow contribution.
When to use something else
- You need source fractions from tracer data; use chemical or isotope mass-balance hydrograph separation.
- You want low-flow design statistics; use flow duration and low-flow frequency analysis.
Assumptions and requirements
- Regular (preferably daily) flows without long gaps; gaps are bridged as if consecutive.
- Filter parameters are set for daily data; BFImax should reflect aquifer type (about 0.8 perennial porous, 0.5 ephemeral, 0.25 hard rock).
- Baseflow starts equal to the first flow value, so the first weeks depend on initialisation.
What the analysis reports
- Baseflow index for each filter
- Total baseflow and quickflow volumes
- Recession constant estimated from recession segments
- Baseflow series plot
How to report it
The Lyne-Hollick filter (alpha = 0.925, three passes) gave a baseflow index of [value], and the Eckhardt filter (a = [value], BFImax = [value]) gave [value].
Common variants
자주 쓰는 설정
The same analysis with settings already chosen. Each runs Baseflow Separation (Lyne-Hollick and Eckhardt Filters) itself, at the same price.
- Baseflow Separation (Eckhardt Filter) — filter set to “eckhardt”
- Baseflow Separation (Lyne–Hollick Filter) — filter set to “lyne_hollick”
Related methods
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with reference values computed independently in the test suite.
독립 계산. 시험에서 따로 계산한 참조값 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Baseflow Separation (Lyne-Hollick and Eckhardt Filters) on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.