Skip to content

Methods · Environmental statistics · Hydrology · Baseflow Separation (Lyne-Hollick and Eckhardt Filters)

Baseflow Separation (Eckhardt Filter)

Separates baseflow from streamflow with Eckhardt's two-parameter recursive filter, which uses a recession constant and a maximum baseflow index.

기저유출 분리(Eckhardt 필터) — 감수 상수와 최대 기저유출 지수를 쓰는 Eckhardt의 2모수 재귀 필터로 하천 유량에서 기저유출을 분리합니다.

Runs Baseflow Separation (Lyne-Hollick and Eckhardt Filters) with: filter set to “eckhardt”.

기본 방법(Baseflow Separation (Lyne-Hollick and Eckhardt Filters))에 다음 설정을 고정해 실행합니다: filter = eckhardt.

How much of our river flow is baseflow, using a filter that respects aquifer type?

하천 유량 가운데 기저유출이 얼마인지 대수층 특성을 반영하는 필터로 알고 싶어요.

Eckhardt's filter caps the baseflow fraction at BFImax, which you can set for porous or hard-rock aquifers. The entry fixes filter = eckhardt in Baseflow Separation (Lyne-Hollick and Eckhardt Filters); the rest of the output follows Baseflow Separation (Lyne-Hollick and Eckhardt Filters).

When to use Baseflow Separation (Eckhardt Filter)

When to use something else

What you still provide

Assumptions and requirements

The same as for Baseflow Separation (Lyne-Hollick and Eckhardt Filters):

What the analysis reports

The output of Baseflow Separation (Lyne-Hollick and Eckhardt Filters), with the preset shown in the settings:

How this is validated

검증 근거

This variant runs the same engine as Baseflow Separation (Lyne-Hollick and Eckhardt Filters) with the settings above fixed, so the evidence is that method’s: compared with independent computations. No separate checks of this preset are claimed. Read the base method’s validation record.

이 설정 묶음은 Baseflow Separation (Lyne-Hollick and Eckhardt Filters)와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.

Other variants of Baseflow Separation (Lyne-Hollick and Eckhardt Filters)

Run this variant

Data you need
a table (CSV or Excel) with a time variable and an outcome variable
Price
Same as Baseflow Separation (Lyne-Hollick and Eckhardt Filters): 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
Checking
Compared with independent computations, as recorded for Baseflow Separation (Lyne-Hollick and Eckhardt Filters) (see its checks)
Before you pay
A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.

Preset ID Q09012-V01 · Variant of Q09012 · Reviewed 2026-10-25