Baseflow Separation (Lyne–Hollick Filter)
Separates baseflow with the Lyne–Hollick one-parameter digital filter applied in several forward and backward passes.
기저유출 분리(Lyne–Hollick 필터) — Lyne–Hollick 1모수 디지털 필터를 앞뒤로 여러 번 적용해 기저유출을 분리합니다.
Runs Baseflow Separation (Lyne-Hollick and Eckhardt Filters) with: filter set to “lyne_hollick”.
기본 방법(Baseflow Separation (Lyne-Hollick and Eckhardt Filters))에 다음 설정을 고정해 실행합니다: filter = lyne_hollick.
What baseflow index does the classic Lyne–Hollick filter give for my gauge?
고전적인 Lyne–Hollick 필터로 우리 관측소의 기저유출 지수를 구하면 얼마인가요?
Lyne–Hollick with α around 0.925 and three passes is a common default in hydrology. Behind it is Baseflow Separation (Lyne-Hollick and Eckhardt Filters) with filter = lyne_hollick already set; checks and report are the same as for Baseflow Separation (Lyne-Hollick and Eckhardt Filters).
When to use Baseflow Separation (Lyne–Hollick Filter)
- You want results comparable to published baseflow indices.
- Only daily streamflow is available.
When to use something else
- You have recession analysis to set a physical parameter; Eckhardt's filter can use it.
- You want to try other settings side by side; open Baseflow Separation (Lyne-Hollick and Eckhardt Filters) and set the options yourself.
What you still provide
- Data: a table (CSV or Excel) with a time variable and an outcome variable.
Assumptions and requirements
The same as for Baseflow Separation (Lyne-Hollick and Eckhardt Filters):
- Regular (preferably daily) flows without long gaps; gaps are bridged as if consecutive.
- Filter parameters are set for daily data; BFImax should reflect aquifer type (about 0.8 perennial porous, 0.5 ephemeral, 0.25 hard rock).
- Baseflow starts equal to the first flow value, so the first weeks depend on initialisation.
What the analysis reports
The output of Baseflow Separation (Lyne-Hollick and Eckhardt Filters), with the preset shown in the settings:
- Baseflow index for each filter
- Total baseflow and quickflow volumes
- Recession constant estimated from recession segments
- Baseflow series plot
How this is validated
검증 근거
This variant runs the same engine as Baseflow Separation (Lyne-Hollick and Eckhardt Filters) with the settings above fixed, so the evidence is that method’s: compared with independent computations. No separate checks of this preset are claimed. Read the base method’s validation record.
이 설정 묶음은 Baseflow Separation (Lyne-Hollick and Eckhardt Filters)와 같은 엔진으로 돕니다. 검증 근거는 기본 방법의 것이며, 이 설정만 따로 검증했다고 주장하지 않습니다.
Other variants of Baseflow Separation (Lyne-Hollick and Eckhardt Filters)
Run this variant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- Same as Baseflow Separation (Lyne-Hollick and Eckhardt Filters): 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Compared with independent computations, as recorded for Baseflow Separation (Lyne-Hollick and Eckhardt Filters) (see its checks)
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.