Measurement System Linearity and Bias Study
A measurement system linearity and bias study measures parts with known reference values repeatedly and regresses the bias (measured minus reference) on the reference value to check whether bias changes across the operating range.
측정시스템 선형성·편의 연구는 기준값을 아는 부품을 반복 측정하고, 편의(측정값−기준값)를 기준값에 회귀해 측정 범위에 따라 편의가 달라지는지 보는 방법입니다.
Is my gauge biased, and does its bias change across the measurement range?
측정기에 편의가 있는지, 그리고 측정 범위에 따라 편의가 달라지는지 확인하고 싶어요.
Bias is computed for every reading as measured value minus reference value and tested against zero with a t test at each reference value. Regressing bias on the reference value gives the linearity slope; a slope or intercept that differs from zero, or a zero-bias line outside the confidence band, indicates a linearity or bias problem.
When to use Measurement System Linearity and Bias Study
- You have reference parts or standards spanning the gauge's operating range, each measured several times.
- You need %linearity and %bias relative to process variation or tolerance for an MSA report.
- You want to know whether the gauge needs recalibration at the ends of its range.
When to use something else
- You want to split measurement variation into repeatability and reproducibility across operators; use a gage R&R study.
- There are no known reference values; use a method comparison such as Bland-Altman or Deming regression.
Assumptions and requirements
- Reference values are known with negligible uncertainty.
- Residuals of the bias regression are approximately normal with constant variance across references.
- Readings are independent.
What the analysis reports
- Bias with t test and confidence interval at each reference value
- Linearity slope and intercept with standard errors, CIs and p values
- %linearity and, with process variation or tolerance, linearity and %bias
- Whether the zero-bias line lies within the 95% confidence band
How to report it
The bias regression slope was [value] (95% CI [[value], [value]]), t([df]) = [value], p = [value], with an average bias of [value] ([value]% of process variation); the zero-bias line [value] within the confidence band.
Related methods
How this method is validated
이 방법의 검증 근거
- Automated tests. Checked by automated run tests; no external reference comparison is recorded yet.
자동 시험. 자동 실행 시험을 거칩니다. 외부 참조값과 대조한 기록은 아직 없습니다.
Run Measurement System Linearity and Bias Study on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Automated run tests; no external reference comparison yet
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.