Multi-Reader Multi-Case ROC Analysis (Obuchowski-Rockette, DBM)
Multi-reader multi-case ROC analysis compares the areas under ROC curves of imaging modalities read by several readers on the same cases, treating readers and cases as random samples.
다판독자 다증례 ROC 분석은 여러 판독자가 같은 증례를 여러 영상 방식으로 판독했을 때 판독자와 증례를 무작위 표본으로 보고 방식 간 ROC 곡선 아래 면적을 비교하는 방법입니다.
Five radiologists read the same 200 images with two modalities; is the AUC of the new modality higher, generalising to other readers and cases?
영상의학과 의사 5명이 같은 영상 200건을 두 가지 방식으로 판독했는데, 새 방식의 AUC가 더 높다고 다른 판독자와 증례로 일반화할 수 있나요?
Each reader-modality AUC is estimated by the trapezoidal rule, their covariances are estimated by jackknife or DeLong methods, and the Obuchowski-Rockette test with Hillis denominator degrees of freedom compares modalities; the DBM pseudovalue analysis gives the same result with jackknife covariance. The output reports AUCs by reader and modality, the reader-averaged difference with its confidence interval, the F statistic, ddf, p-value and variance components.
When to use Multi-Reader Multi-Case ROC Analysis (Obuchowski-Rockette, DBM)
- Several readers rate the same cases under two or more modalities in a fully crossed design.
- You want conclusions that generalise to both the reader and the case populations.
- Ratings are confidence scores or probabilities with a known truth for each case.
When to use something else
- There is a single reader; compare correlated ROC curves with DeLong's test instead.
- Readers read different cases (split-plot design); use a model built for split-plot MRMC data instead.
Assumptions and requirements
- Fully crossed design: every reader rates every case under every modality.
- Truth is fixed per case and coded 0/1.
- Higher ratings indicate greater suspicion of disease.
- A negative Cov2 - Cov3 is set to zero in the test denominator (Hillis constraint).
What the analysis reports
- AUC by reader and modality and reader-averaged AUC with CI
- AUC difference with CI for each modality pair
- F (or chi-square) statistic, Hillis ddf and p-value
- OR covariance terms and variance components
How to report it
In a multi-reader multi-case study ([value] readers, [value] cases), the reader-averaged AUC was [value] for modality A and [value] for modality B; the OR test gave F(1, [value]) = [value], p = [value], AUC difference = [value] (95% CI [[value], [value]]).
Related methods
- ROC-AUC Curve Analysis
- Comparison of Two Diagnostic Tests on the Same Subjects
- Comparison of Two Diagnostic Tests on the Same Subjects
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with scikit-learn and direct computations (formulas, enumeration or simulation).
독립 계산. scikit-learn·직접 계산(식·열거·모의실험) 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Multi-Reader Multi-Case ROC Analysis (Obuchowski-Rockette, DBM) on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable, predictor (feature) columns, a unit (entity) ID and a grouping variable
- Price
- 900 credits for one analysis up to 10,000 rows (complexity level 5); larger or wider data costs more. Optional methodologist review: 3600 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.