Overlapping Peak Deconvolution (Multi-Peak Curve Fitting)
Overlapping peak deconvolution fits a sum of peak functions such as Gaussian, Lorentzian, pseudo-Voigt, Voigt or exponentially modified Gaussian, plus an optional baseline, to resolve overlapping bands into individual areas.
겹친 봉우리 분리(디컨볼루션)는 가우스·로렌츠·의사 보이트·보이트·지수변형 가우스 같은 봉우리 함수의 합과 기저선을 함께 적합해 겹친 띠를 개별 면적으로 분리하는 방법입니다.
Two or three peaks in my chromatogram or spectrum overlap; how can I estimate each peak's position, width and area with uncertainty?
크로마토그램이나 스펙트럼에서 봉우리 두세 개가 겹쳐 있는데, 각 봉우리의 위치·폭·면적과 그 불확도를 어떻게 추정하나요?
Fit all peaks jointly by nonlinear least squares, starting from detected maxima and second-derivative shoulders, with the peak shape and baseline chosen for the technique. Report centres, widths, heights and areas with standard errors from the Jacobian, choose the number of peaks by AIC, and inspect the residual plot for missed peaks.
When to use Overlapping Peak Deconvolution (Multi-Peak Curve Fitting)
- Peaks overlap too much for simple integration between valleys.
- You need relative areas of overlapping components with standard errors.
- The peak shape is roughly known (Gaussian, Lorentzian, Voigt-like or tailing).
When to use something else
- Peaks are well separated; use Peak Detection and Integration.
- Many components overlap in several samples; use multivariate curve resolution or PARAFAC.
Assumptions and requirements
- The x axis is the time role and the signal is the outcome (up to 20,000 points; 3,000 for the exact Voigt shape); AIC selection tries up to 6 peaks.
- Each component follows the chosen peak shape.
- Errors are independent with constant variance (for the SEs and AIC).
- The baseline is flat, linear, or removed by asymmetric least squares beforehand.
What the analysis reports
- Peak centres and areas with standard errors, FWHM and heights
- Area fractions
- R squared, RMSE, AIC and AIC by number of peaks
- Residual plot and Durbin-Watson check
How to report it
A [value]-peak [shape] model with [baseline] baseline fitted the signal with R² = [value] (AIC = [value]); the largest peak at [value] (SE [value]) had area [value] (SE [value], [value]% of the total).
Related methods
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with direct computations (formulas, enumeration or simulation).
독립 계산. 직접 계산(식·열거·모의실험) 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Overlapping Peak Deconvolution (Multi-Peak Curve Fitting) on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.