Peak Detection and Integration
Peak detection and integration locates local maxima in a signal that exceed prominence and spacing thresholds and measures each peak's position, height, width at half height and area.
봉우리 검출·적분은 신호에서 돌출도와 간격 기준을 넘는 국소 최댓값을 찾아 위치, 높이, 반치폭, 면적을 재는 방법입니다.
How do I find and integrate the peaks in my chromatogram or spectrum automatically?
크로마토그램이나 스펙트럼의 봉우리를 자동으로 찾고 면적을 구하려면 어떻게 하나요?
After optional baseline subtraction, local maxima whose prominence exceeds a noise-based threshold are kept, their full width at half maximum is measured, and the area is integrated with the trapezoidal rule between the valleys on each side. Gaussian or Lorentzian shapes can be fitted to each peak to give analytic areas and widths.
When to use Peak Detection and Integration
- Chromatograms, spectra or other signals with distinct peaks need positions and areas.
- You want reproducible peak picking with thresholds tied to the noise level.
- You want signal-to-noise ratios for each peak.
When to use something else
- Peaks overlap heavily and need joint deconvolution; use a multi-peak curve-fitting model.
- You want extreme values of a random process over a threshold; use a peaks-over-threshold (GPD) analysis.
Assumptions and requirements
- Samples are equally spaced along the time or wavelength axis.
- The baseline is smooth relative to the peaks (or has been removed).
- Peaks are separated well enough for valley-to-valley integration.
What the analysis reports
- Peak table with position, height, prominence, FWHM, start, end and area
- Signal-to-noise ratio per peak
- Fitted Gaussian or Lorentzian centre, width and area (optional)
- Number of peaks, noise SD and threshold used
How to report it
[value] peaks were detected with prominence ≥ [value]; the main peak at [value] had height [value], FWHM [value] and area [value] (S/N = [value]).
Related methods
How this method is validated
이 방법의 검증 근거
- Automated tests. Checked by automated run tests; no external reference comparison is recorded yet.
자동 시험. 자동 실행 시험을 거칩니다. 외부 참조값과 대조한 기록은 아직 없습니다.
Run Peak Detection and Integration on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Automated run tests; no external reference comparison yet
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.