Population Bioequivalence (FDA Aggregate Criterion)
Population bioequivalence compares the whole distribution of a pharmacokinetic measure under the test and reference formulations. The aggregate criterion adds the squared difference in log means to the difference in total variances and scales it by the reference total variance, or by a fixed constant when the reference variance is small.
집단 생물학적 동등성은 시험약과 대조약에서 약동학 지표의 분포 전체를 비교합니다. 통합 기준은 로그 평균 차이의 제곱과 총분산의 차이를 더한 뒤 대조약의 총분산으로, 또는 대조약 분산이 작을 때는 정해진 상수로 나누어 판단합니다.
Are the test and reference formulations interchangeable for a patient starting treatment, taking both the mean and the total variability into account?
평균과 전체 변동을 함께 고려할 때, 새로 투약을 시작하는 환자에게 시험약과 대조약을 바꿔 써도 될까요?
The method estimates the log-scale mean difference and the total variances of test and reference from a two-period crossover, forms the linearised criterion of the 2001 FDA guidance, and computes its one-sided 95% upper confidence bound with the moment and delta-method approach of Chow, Shao and Wang (2003). Population bioequivalence is shown when the bound is below zero and the geometric mean ratio lies within 0.80 to 1.25.
When to use Population Bioequivalence (FDA Aggregate Criterion)
- You need prescribability: whether a new patient may start on either formulation.
- The test formulation may change the variability of exposure, not only its mean.
- You have a standard 2x2 crossover with one observation per subject and period.
When to use something else
- You only need the regulatory mean comparison: use Average Bioequivalence Analysis
- You want a posterior probability for the mean ratio: use Bayesian Average Bioequivalence Analysis (2x2 Crossover)
- Your design replicates formulations within subjects (this implementation covers the 2x2 crossover): use Average Bioequivalence Analysis
Assumptions and requirements
- Log-transformed responses are approximately normal
- No unequal carryover between periods
- Each subject has both periods observed
- Enough subjects for the asymptotic bound (roughly 24 or more)
What the analysis reports
- Log mean difference and geometric mean ratio
- Total variances of test and reference
- Population bioequivalence ratio and linearised criterion
- One-sided 95% upper bound and decision
- Choice of reference- or constant-scaled criterion
How to report it
Using the reference-scaled population bioequivalence criterion (theta_P = [value]), the linearised criterion was [value] with a one-sided 95% upper bound of [value]; the geometric mean ratio was [value], so population bioequivalence was [shown/not shown].
Related methods
- Average Bioequivalence Analysis
- Bayesian Average Bioequivalence Analysis (2x2 Crossover)
- Equivalence Test (TOST)
How this method is validated
이 방법의 검증 근거
- Independent computation. 2 reference tests compare the results with direct computations (formulas, enumeration or simulation).
독립 계산. 직접 계산(식·열거·모의실험) 대조 참조 시험 2건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Population Bioequivalence (FDA Aggregate Criterion) on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable, a unit (entity) ID, a treatment indicator and a time variable
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.