Standard Addition Analysis
Standard addition analysis estimates an analyte's concentration by adding known amounts to portions of the sample, regressing signal on amount added and extrapolating the line to its x-intercept.
표준물첨가법 분석은 시료 일부에 알려진 양의 분석물을 더해 신호를 첨가량에 회귀한 뒤, 직선을 x절편까지 외삽하여 시료 속 농도를 추정하는 방법입니다.
My sample matrix suppresses the instrument signal, so an external calibration curve gives biased results; how do I quantify the analyte with standard additions?
시료 매트릭스가 기기 신호를 억제해서 외부 검량선으로는 결과가 치우칩니다. 표준물첨가법으로 정량하려면 어떻게 하나요?
Spike equal portions of the sample with increasing known amounts, measure the signal and fit a straight line of signal on amount added; the sample concentration is the intercept divided by the slope, multiplied by any dilution factor. Report the line, the concentration with its standard error s/b·sqrt(1/n + ȳ²/(b²Sxx)) and a t-based confidence interval.
When to use Standard Addition Analysis
- Matrix effects change the sensitivity (slope) so external standards in clean solvent would be biased.
- Several spiked portions of the same sample can be measured.
- The signal is linear in concentration over the spiked range.
When to use something else
- The matrix has no effect on sensitivity and many samples must be measured; use linear calibration with inverse prediction.
- There is a constant (additive) background signal that the method cannot remove; correct it with a proper blank or use a calibration with blank subtraction.
Assumptions and requirements
- Signal is linear in the total amount of analyte over the whole range including the extrapolation.
- No additive background signal, so zero analyte gives zero signal.
- Errors are in the signal only and have constant variance.
What the analysis reports
- Intercept and slope with standard errors and confidence intervals
- Concentration (a/b times dilution) with standard error and confidence interval
- R², residual normality check and a lack-of-fit test when additions are replicated
How to report it
Standard addition (n = [value]) gave y = [value] + [value]x (R² = [value]); the sample concentration was [value] (SE = [value], 95% CI [value] to [value]).
Related methods
How this method is validated
이 방법의 검증 근거
- Published value. A test reproduces published reference values.
출판값. 출판된 참조값 재현 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Standard Addition Analysis on Quorant
- Data you need
- a table (CSV or Excel) with an outcome variable and predictor (feature) columns
- Price
- 250 credits for one analysis up to 10,000 rows (complexity level 2); larger or wider data costs more. Optional methodologist review: 1200 credits.
- Checking
- Reproduces published reference values
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.