Fractional-Octave Band Analysis
Fractional-octave band analysis splits a sound-pressure recording into octave or third-octave bands with a bank of band-pass filters and reports the equivalent continuous level in each band and overall.
분수 옥타브 대역 분석은 음압 신호를 옥타브 또는 1/3 옥타브 대역통과 필터 묶음으로 나누어 대역별 등가 소음도와 전체 소음도를 구하는 방법입니다.
I recorded sound pressure with a calibrated microphone; how do I get third-octave band levels and an A-weighted total?
보정된 마이크로 음압을 녹음했는데, 1/3 옥타브 대역별 소음도와 A 가중 전체 소음도는 어떻게 구하나요?
Filter the calibrated pressure signal through base-10 octave or third-octave band-pass filters and compute each band's equivalent level as 10 log10 of the mean squared pressure over the reference pressure squared. The A- or C-weighted total is obtained by adding the weighting at each band centre and summing the band energies.
When to use Fractional-Octave Band Analysis
- You have a calibrated pressure (or vibration) time signal and need band levels for noise assessment or reporting.
- You want to see which frequency bands dominate a noise spectrum in standard octave or third-octave resolution.
- You need an approximate A- or C-weighted overall level from band levels.
When to use something else
- You need narrow-band frequency detail such as individual tones; use a Welch power spectral density.
- You need a certified sound level meter reading with time weighting (Fast/Slow); use a class-1 instrument or a time-domain weighting filter.
Assumptions and requirements
- The signal is calibrated in pascals (or a calibration offset in dB is supplied).
- The sampling rate is well above the highest band of interest.
- The record contains enough cycles of the lowest band (at least 10 here).
What the analysis reports
- Band centre, edge frequencies and band Leq table
- Broadband overall level and energy sum of the bands
- A/C-weighted overall level by band summation
- Loudest band
How to report it
The equivalent continuous level was [value] dB re 20 µPa ([value] dB(A)); the loudest third-octave band was [value] Hz at [value] dB.
Related methods
- Welch and Multitaper Power Spectral Density
- Digital Filtering
- Room Reverberation Time from Impulse Response (Schroeder)
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with reference values computed independently in the test suite.
독립 계산. 시험에서 따로 계산한 참조값 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Fractional-Octave Band Analysis on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.