Room Reverberation Time from Impulse Response (Schroeder)
Room reverberation time estimation from an impulse response (Schroeder method) backward-integrates the squared response and fits the decay curve to obtain EDT, T20 and T30, together with clarity C50/C80 and definition D50.
임펄스 응답 잔향시간 추정은 제곱한 응답을 끝에서부터 역적분(슈뢰더)한 감쇠곡선에 직선을 맞추어 EDT, T20, T30과 명료도 C50·C80, 선명도 D50을 구하는 방법입니다.
I measured a room impulse response; how do I calculate T30, EDT and C80 per octave band?
실내 임펄스 응답을 측정했는데, 옥타브 대역별 T30, EDT, C80은 어떻게 계산하나요?
Band-filter the impulse response, square it and integrate backwards from the end to get the Schroeder decay curve, compensating for background noise. Fit straight lines to the −5 to −25 dB and −5 to −35 dB parts for T20 and T30 and to 0 to −10 dB for EDT, and compute clarity from the early-to-late energy ratio.
When to use Room Reverberation Time from Impulse Response (Schroeder)
- You have a measured or simulated room impulse response.
- You need ISO 3382-style room acoustic parameters by octave or third-octave band.
- You want to compare rooms or treatments on reverberation and clarity.
When to use something else
- Only a noise recording without a defined excitation is available; use an interrupted-noise or blind estimation method.
- The decay range is under about 35–45 dB; report T20 or EDT only, or remeasure with a better signal-to-noise ratio.
Assumptions and requirements
- Approximately exponential (linear in dB) energy decay in the evaluation range.
- Enough dynamic range above the noise floor for the chosen range.
- A single onset that can be detected at 20 dB below the peak.
What the analysis reports
- EDT, T20, T30 by band and broadband
- C50, C80 and D50
- Decay range and whether noise compensation was applied
- Broadband Schroeder decay curve
How to report it
The mid-frequency reverberation time was T30 = [value] s (EDT = [value] s), and clarity C80 = [value] dB.
Related methods
How this method is validated
이 방법의 검증 근거
- Independent computation. 1 reference test compares the results with reference values computed independently in the test suite.
독립 계산. 시험에서 따로 계산한 참조값 대조 참조 시험 1건 통과.
Tolerances are relative differences (absolute differences for values near zero). R comparisons and reference tests are re-run before each release of the analysis engine.
허용오차는 상대 차이입니다(0 근처 값은 절대 차이). R 대조와 참조 시험은 분석 엔진을 배포할 때마다 다시 돌립니다.
Run Room Reverberation Time from Impulse Response (Schroeder) on Quorant
- Data you need
- a table (CSV or Excel) with a time variable and an outcome variable
- Price
- 400 credits for one analysis up to 10,000 rows (complexity level 3); larger or wider data costs more. Optional methodologist review: 1800 credits.
- Checking
- Compared with independent computations
- Before you pay
- A free pre-analysis diagnosis checks your data and gives an exact quote; nothing is deducted until you approve it.